Yes,something funny happened please ignore my message ..
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at
James,on what zOS Level you are I execute the $d m command and it
immediately shows me message in the JESMSGLG so I guess something with
your profile ..did you check with other user profile or on other
system?
--
For IBM-MAIN
if you guys have connect direct as third party product spool to spool
transfer is pretty easy stuff..
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET
Before I talk to SAS thought to cross post here..
I am exploiting mailing service using SAS however on particular lpar only
it seems to be not working ..below is my JCL.
//SENDMAIL EXEC SASMSTR,
// OPTIONS='EMAILSYS=SMTP EMAILHOST=xxx.xxx.xxx.xxx'
Forgot to add it does work with IEBGENER ..Thanks
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at
Apology if somebody says it's in archieves since I could not locate it..
I would like to know where IBM documentated the hexadecimal convertion to
the device type ..example below DEVTYPE--X'78048083' ..I know
x'8xxx' shows tape series however would like to know more descriptive
Thierry,
Here I try giving you answer with my test example...
1) I ran a test job (as below)
J E S 2 J O B L O G -- S Y S T E M 1 X 0 1 --
N O D
05.25.48 JOB00596 THURSDAY, 17
Hi,
Does someone having a copy of VBSFIX module..could you please share it with
me..i used to have one lost however somewhere..
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
Hi All,
Today we met with a situation where one of the change with the XCF Dataset
move did not go well and we had a system running with default WLM Policy
we starting conference to go back to the Old XCF WLM dataset say the
situation was like this.
Current/Active Sysplex WLM dataset
Hi Team,
Any idea where I am missing point..
I am running a Rexx exec in batch job which check the ENQ on the dataset
every 6 second and idea is to do continuously in loop till the Time
parameter on the job doesn't complete..say for example I have idea for 30
minute however during testing I
You might be interested in apar OA28814 ...we faced it..
OA28814: $DISTERR XLOSTJQE AFTER NJE LINE ERROR
http://www-01.ibm.com/support/docview.wss?
rs=0q1=OA28814uid=isg1OA28814loc=en_UScs=utf-8cc=uslang=en
--
For IBM-MAIN
Thanks All/Martin..
As suggested DISP=MOD should replace DISP=OLD ..it has raised question for
me since Mod is going to keep adding data in the existing member and that's
where it fall down..
Does somebody has thought on that..?? i still see option to breakdown step
into 3 separate steps to
Hi,
Below are the issue we found with one of the PDS library we had..this has
occured 3 times and I am trying to understand what are the possibilities
because of which it happening ..has anyone seen it before...ofcourse I have
checked the GRSplex and nothing unusual for this dataset..
PDSMAN
Hi Terry,
Thanks !!! Yes that's correct we have traditional PDS and not PDSE... I thought
same even suggested application programmer to split the writing to
members however could not prove it again they had been using DISP=OLD
which put my thought in question...
There JCL look like this
Hi Team,
Does anyone having experience installing Hercules Emulator on Window Vista?? i
have tried however looks to me Vista is not supported any comment please?
Again if someone has any document which help doing so please send me offline..
Though I have gone with manuals however could not find where I could
easily see Via Audit or report or any other function to see daily
DFHSM function log associated with the TSO userid..
for example ...Somebody issue a HSEND HOLD MIGRATION on the user who
issued this command will see below
Off List Post*
Does anyone have any experience for the System z Technical specialist exam?
Test 000-428 ?
I have been trying to get some documents to read However could not find
anything related to it which cover the subject for this certification..
I used first time utility FTPENCRD to encrypt the tersed data before FTPing
to IBM ..and then provided them the encrypt key being used at the time of
encryption with the utility ...I read it's a PUTDOC from IBM where key is
generated with CYPHER_KEY however to read some more information on this
Hi List,
Has anyone seen this error message ...I looked in the manuals and more than
below illustration could not find anything.
IEC161I 008-0571 messages whenever the
dataset is VSAM and is not RLS. The message does not indicate a
problem, but is a nuisance
I see below error message in the
19 matches