Dear listers
I have a requirement to produce daily report on user access to Host based
applications (CICS + TSO - Green screens). I do have SAS, MXG, RACF and was
thinking of using IRRADU00 output and SAS/MXG (SMF type 30 subtype 1 and 80
records) but not sure if it will include CICS
Dear Listers
I have been requested to modify a panel to verify that user input a valid date
(MM/DD/YY) and the
input date is no more then 3 months away (roughly speaking).
Body section of my panel is
+ START DATE %===_STRT + REVOKE DATE %===_RVK +
and in the PROC, for Date
Just to add to my previous request, I have to define new coupling facility
datasets to enbale support for newer protocols and do not know **yet** how to
pouplate them with our exisitng sysplex policies.. May I IPL an LPAR (z/OS
1.13) with the new coupling facility datasets and then definine
Thank you all.
Mr Kawkabani, I will use CFRMPOL to refer to newly created policy. What about
ARM and SFM policies that I have created using IXCMIAPU and are named
differently. How can I use them.
Still searching for how to create new CDS, BPXMCDS, LOGR (hundreds of
structures)and WLM policies
Dear Lister
We are replacing our mainframe i.e. Power off old mainframe, rip it apart,
move power supply, I/O cages, OSA cards on to the new box and IML/IPL new CF
and other LPARs.
I have defined brand new Coupling datasets , ARM, BMPXMCDS, CFRM, SFM, LOGR,
WLM dataset and have updated
Dear listers
Please point me in the right direction.. I am trying to send a small VB, LRECL
500 bytes file as an attachment via SMTP from my z/OS 1.13 without much
success..
is it possible? any working smaple?
regards
Munif
Hello Listers
We have virtual tapes, virtual drives and I am submitting a batch job to read
data from 40+virtual tapes but our MTL - RMM - zOS 1.13 system is not mounting
/ using more that 11 tapes in parallel.
We have got 120+ virtual drives and available and system is not busy..
regards
Thanks Radoslaw,
yes all vurtual devices are online and data volumes available
job reads data from different systems / components - CMF / RMF / TMON / IMS/
DB2 / data collectors etc and then sort them.
IBM RMM HSM OAM and LUMINEX MTLs defined as Storage class / storage group in
SMS.
Thanks Rick
Thats exactly what I am finding out.. It does not matter what Linkage editor
statements I use (Thanks Steve) I cannot create multiple entry points in a
PL/1 load module and make them independent runnable unit.
If I am not asking for too much, can someone please provide a working
Dear Listerr
I am trying to create multiple entry point for single PL/1 Load module. My
source is
MSTST : PROC OPTIONS (MAIN) REORDER;
DEFAULT RANGE(*) STATIC;
PUT SKIP LIST(' MSTST ENTRY POINT');
Dear Listers
I am trying to activate a switched node and its failing with
-V NET,ID=X,ACT
IST097I VARY ACCEPTED
IST489I VARY ACT FOR ID = XX CONTINUES - CANNOT DEFINE NODE: XXPU
Dear Listers
I have been asked to providetelnet 3270 access to an application running on
remote host connectned via VPN - Eneterprise extender. Can I define alternate
IP for faiolver on that remote PU SWNET. Do I have to open telnet port 23 (7723
for SSL) beside port 12000-12004.. Any other
tried RO CONNECT and got
IEE305I CONNECT COMMAND INVALID
cheers.. Munif
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Dear Listers
I am sure it must have been discussed before but i can not find any
reference..
Without using FTP / XEQ / Route (in Batch / SDSF) is there a way possible to
route a command to another system in a Plex and receive the output from the
command - Intercatively ..lets say from TSO.
Thanks Chris
Problem with Netview solution is,
first we do not have it and
with our automation tool - BMC solution, we have to authorize console ((S)
MCS) for these commandsn and its not interactive (from TSO).
regards Munif
to apply a sysmod what are the SMP DATASETS required besides global /
target zones CSI and smppts dataset.
thanks
Munif.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu
Duh!!! my EE connection is still not working..
Did change BN=YES. dfined new ADJCLUST for the remote network on this
gateway SSCP.
on displaying ADJCLUST
IST2207I DEFINED TABLE FOR remote_network
IST2209I BNDYN = LIMITED FROM ADJCLUST TABLE
Thank Chris (Mason)
You are a living encyclopaedia.
I was required another CDRSC entry to get it going. Now my next bigger
headache. we are migrating from old DDN link to enterprise extender and Other
party will not give *some new* applications (non production) to test it. As a
mainframer,
Dear listers
I have got CP - CP sessions going between two different mainframe networks,
lets say NETA.A and NETB.B using Enterprise extender, and now would like to
establish connectivity between two CICS - CICSA (running on NETA.A) and
CICSB(running on NETB.B). What do i need to define:
A)
Dear listers
I am interested in implementing some kind of session level encryption for SNA
data (LU 6.2 \ Enterprise Extender) but do not have a crypto processor.
Is it possible to do Session level encryption. IPSEC still far away for us.
regards
Munif
Hi
I have started two db2 data sharing members on two different z/OS images in
a parallel Sysplex and can connect to them via group attachment name (SSID)
in a batch job. My problem is If i shut down one of the member I am not able
to use group attachment name on that z/OS image to
Thanks a lot Terry,
We are trying out DB2 data sharing mostly for DB2 availability required by our
BATCH (DSN) and CICS (DB2C).
I am not sure what are the other components required to achieve this. DDF?
Syspelx distributor? Anything else?. Our batch is under WLM but can not find
any thing
Dear Listers,
I would like to enable SYSNAME ON (ISPF Command ) for all TSO users. So far
i could not find a way to issue ISPF command from REXX / CLIST in my logon
procs. Even tried to modify ISPCFIGU using TSO ISPCCONF (with increament
VERSION_LEVEL_OF_SITEWIDE_DEFAULTS )
Dear listers,
We are *replacing* our Z890 CPU by Z9 BC. Z9 BC does not cick in unless we
power off Z890.
I would appreciate if you can guide me or provide me pointers in the right
direction:
a) We are moving our OSA cards and have downloaded OSA configurations using
OSA/SF and plan it to
I am migrating Ent COBOL for Z/OS OS/390 3.4 and z/OS 1.7 in one of our
parallel sysplex system replacing IBM COBOL for OS/390 VM 2.2.0 and z/OS
1.4. My concern is about the run time environment and upward compatibility
of COBOL /LE especially for CICS – DB2 – COBOL programs compiled in z/OS
Is there any easy way to find out coexistence and fallback maintenance
required for our CICS/DB2 subsystem for z/OS migration from 1.4 to 1.7. PSP
bucket search for ZOSV1R7 does not show anything exclusive for CICS/DB2.
Your help is much appreciated.
regards,
Munif Sadek
Please help me in upgarding our production JES2PLEX Checkpoint level from
OS/390 R 4 to z/OS 1.2 level. we are at z/OS 1.4 and
$HASP895 $DACTIVATE
$HASP895 JES2 CHECKPOINT LEVEL IS NOW OS/390 RELEASE 4
$HASP895 A TOTAL OF 1826 4K RECORDS ARE REQUIRED FOR $ACTIVATE.
$*HASP895 CKPT2 IS TOO
I have been asked to increase DUMPSAPCE in our coupling facility (% Storage
allocation vise - existing dumpspace is 1% of coupling facility total
space), although we have not seen any problems. Is there any IBM
recommedation / ROTs.
regards, munif..
I have defined CFR(Dedicated) and CFS(Shared) channels for my Production CPC
and when I am connecting them, its failing with following HCD message:
Processor X cannot be connected via different control units to the
coupling facility - partition CF01 of processor X.
I am afraid I have/can not
Hi Listers,
I need to increase size of one of the log stream structure in my CFRM Policy
for our production sysplex. Can some one give me list of steps?
Can I update structure size in-place and do I need to include statement only
for the structure whose size I am changing in my IXCMIAPU job
Hi,
Our paging configuration is
PLPA 83% OK 9374 PAGE.PROD.PLPA
COMMON 2% OK 9374 PAGE.PROD.COMMON
LOCAL 0% OK 9374 PAGE.PROD.LOCAL1
LOCAL 0% OK 94CB PAGE.PROD.LOCAL2
LOCAL 0% OK 930F PAGE.PROD.LOCAL3
LOCAL 0% OK 93E4 PAGE.PROD.LOCAL4
Dear listers,
We have tried sftp and did not like it. OPS hated it and even our job
scheduler did not find it very friendly. Now would like to try FTPS. We
have been using SSL for Telnet 3270 although no crypto processor on site.
I did a quick search in our z/OS 1.7 library and did not find
32 matches
Mail list logo