CVAF ERROR TYPE 2 TCB= 008D15C8

2010-10-28 Thread amit
Hi, While running a defrag using ADRDSSU i am getting the following: IEA794I SVC DUMP HAS CAPTURED: 380 DUMPID=020 REQUESTED BY JOB (HPDPEXTI) DUMP TITLE=ICVCMM00 HPDPEXTI CVAF ERROR TYPE 2 TCB= 008D15C8 W/ A=7F3DE02C 0ADR227E (001)-DFRGD(09), CVAF ERROR ON VOLUME P3GE91, CODE

Re: CVAF ERROR TYPE 2 TCB= 008D15C8

2010-10-28 Thread Vernooij, CP - SPLXM
CVAF ERROR TYPE 2 TCB= 008D15C8 W/ A=7F3DE02C 0ADR227E (001)-DFRGD(09), CVAF ERROR ON VOLUME P3GE91, CODE 11,00 0ADR256E (001)-DFRGD(01), AN ERROR OCCURRED WHILE ATTEMPTING TO CONSOLIDATE EXTENTS FOR DATA SET PSD.LSUPC68I i went through the IBM manuals, but maybe lack

Re: CVAF ERROR TYPE 2 TCB= 008D15C8

2010-10-28 Thread amit
) DUMP TITLE=ICVCMM00 HPDPEXTI CVAF ERROR TYPE 2 TCB= 008D15C8 W/ A=7F3DE02C 0ADR227E (001)-DFRGD(09), CVAF ERROR ON VOLUME P3GE91, CODE 11,00 0ADR256E (001)-DFRGD(01), AN ERROR OCCURRED WHILE ATTEMPTING TO CONSOLIDATE EXTENTS FOR DATA SET PSD.LSUPC68I i went through

Re: CVAF ERROR TYPE 2 TCB= 008D15C8

2010-10-28 Thread Roger Lowe
Amit, As part of your DEFRAG job, are you also using the CONSOLIDATE keyword? If so, have a look at APAR OA34585 which is still open and the local fix is to remove the CONSOLIDATE keyword from your DEFRAG job. Roger --