Health CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE)

2011-07-22 Thread Barbara Nitz
Guess what, folks, I am at it again :-) Our newly IPL'd 1.12 system has a lot of new 'stupid' health checks, but this one takes the crown: HZS1002E CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE): AN ERROR OCCURRED, DIAG: 0064_0008

Re: Health CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE)

2011-07-22 Thread Miklos Szigetvari
Hi Return Code Description Programmer Response 100 Catalog Management has detected an error while processing the request. * Reason Code 4: at least one data set entry is returned with an error. * Reason Code 8: at least one catalog entry is returned with an error.

Re: Health CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE)

2011-07-22 Thread Norbert Friemel
On Fri, 22 Jul 2011 02:03:09 -0500, Barbara Nitz wrote: Our newly IPL'd 1.12 system has a lot of new 'stupid' health checks, but this one takes the crown: HZS1002E CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE): AN ERROR OCCURRED, DIAG: 0064_0008 IGGHC103I

Re: Health CHECK(IBMCATALOG,CATALOG_IMBED_REPLICATE)

2011-07-22 Thread Barbara Nitz
HC needs read access to all catalogs for this check. Any RACF messages in syslog? Yes Absolutely clear from rc64, rsn8, right? Thanks for pointing it out, that appears to be the problem. I have asked the racfadmin to authorize HC. Now, where was this action described? Believe me, I have