Hello,
is there anyone that can give me help on how to set a naviquest set of
cmds to run in batch to perform the following tasks:
SG ALTER where I need to change the connection to the lpars from
disnew to enable and then validate and activate sms configuration.
Can you pls give me an help ?
Many
.It wouldn't be too hard to have automation set
something up to enter the SETSMS command after the Validate.
//
Hello,
is there anyone that can give me help on how to set a naviquest set of
cmds to run in batch to perform the following tasks:
SG ALTER where I need
I am still new to Naviquest, so I spent some time in the Naviquest manual.
To add to what Darth said:
The manual specifically states to use the SETSMS command after the
translate and validate. According to the manual, Naviquest is designed
only for testing. Activating moves it into use.
Thank
I have almost zero exposure to NAVIQUEST.
I'm not trying to disparage anyone and this is not the 1st time I've seen
a similar comment - but I have a general question for the group - if you
don't know use NAVIQUEST, how do you test major code changes to SMS?
I've used it extensively found
Hey Darth,
It's been a while since I've seen a Naviquest presentation at Share. How about
signing up to present on this topic? It is a great tool!
Colleen Gordon
--
For IBM-MAIN subscribe / signoff / archive access
Even I'd attend that !!
Alan Schwartz
-Original Message-
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
Behalf Of Colleen Gordon
Sent: Friday, August 14, 2009 2:12 PM
To: IBM-MAIN@bama.ua.edu
Subject: Naviquest
Hey Darth,
It's been a while since I've seen
Hey Darth,
It's been a while since I've seen a NaviQuest presentation at Share. How
about signing up to present on this topic? It is a great tool!
Colleen Gordon
Hi Colleen -
If I can get past budget constraints and can get both permission to go to
Share next year and then also permission
Greetings,
I am in need of NaviQuest SMF Records to Test DAF.
SMF record type 127 is recorded by exit routine
IGDACSSC. The SMF record contains the ACS variables
which are used to generate ACS routine test cases.
The test cases are generated by NaviQuest option 1.3.
Cheers,
Michael
http
I don't know anything about the NaviQuest job, but the syntax is wrong for
ISPSTART, which looks like this:
ISPSTART CMD(xxx parm1 parm2 parm3 ...) ...
In other words, parameters to be passed to CMD xxx must be included within
the parentheses. Parms placed after the closing paren
Thank you
The problem is resolved by tracing the rexx ACBQBAR7. The reason is
the profile of sysin (should be number off or the rexx will terminate with
error).
Best Regard,
Wang Rong
--
For IBM-MAIN subscribe / signoff
Hi all,
Has anybody used the NaviQuest batch job ACBJBAOB? I just tried to use
the ACBQBAR7 command to produce report from DCOLLECT output.Though the JCL
returned zero, but I got a error in SYSTSPRT GENDREP:
READY
PROFILE PREFIX(IBMUSER)
READY
ISPSTART CMD(ACBQBAR7) BATSCRW(132) BATSCRD(27
11 matches
Mail list logo