Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread ibmnew
Joel C I got it.Thanks you very very much! Best Regards, Cai Jin Song > Hi all > > We defined a VSAM file and a GDG base using a user id DBJMP05. > The prefix of DBJMP05 is managed by SMS > SMS routing > SC : > FILTLIST TSOUSERS INCLUDE(DBJMP*) > > WHEN&HLQ =&TSOUSERS >

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Hunkeler Peter (KIUP 4)
>It used to be the case that RACF UPDATE access to all catalogs was >always required to make catalog changes. At somewhere along the line >this SMS exception was documented as an enhancement with MVS release >migration docs. I missed this enhancement. Thanks for the update. -- Peter Hunkeler Cred

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Chase, John
> -Original Message- > From: IBM Mainframe Discussion List [On Behalf Of Hunkeler Peter (KIUP 4) > > >There are only RACF profiles DBJMP05.** for DBJMP05.BDZ3 and > DBJMP05.FAS. > > This is not of interest to the problem. The access was denied when > accessing the catalog (see your ICH4

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Joel C. Ewing
On 03/03/2011 02:13 AM, ibmnew wrote: > Hi all > > We defined a VSAM file and a GDG base using a user id DBJMP05. > The prefix of DBJMP05 is managed by SMS > SMS routing > SC : > FILTLIST TSOUSERS INCLUDE(DBJMP*) > > WHEN&HLQ =&TSOUSERS > SET&STORCLAS = 'SCSTAND' > SG: > F

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Hunkeler Peter (KIUP 4)
Can you try to define a GDG named DBJMP05.BDZ3.GDG and can you try to define a VSAM data set named DBJMP05.FAS.VSAM What happens? -- Peter Hunkeler CREDIT SUISSE AG -- For IBM-MAIN subscribe / signoff / archi

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Hunkeler Peter (KIUP 4)
>There are only RACF profiles DBJMP05.** for DBJMP05.BDZ3 and DBJMP05.FAS. This is not of interest to the problem. The access was denied when accessing the catalog (see your ICH408I). The user is not permitted UPDATE to data set CATALOG.PLEXBDZ3.TSO, at least in the GDG case. And I can't imagi

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread ibmnew
Lizette There are only RACF profiles DBJMP05.** for DBJMP05.BDZ3 and DBJMP05.FAS. Thanks a lot! Jason Cai > Our shop is RACF. > It is single level alias > Our shop is z/OS 1.11. the image is a single image. > > DBJMP05.BDZ3.MAN1 catalog to the same catalog as the GDG. > Thanks a lot! > Jas

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Lizette Koehler
> Our shop is RACF. > It is single level alias > Our shop is z/OS 1.11. the image is a single image. > > DBJMP05.BDZ3.MAN1 catalog to the same catalog as the GDG. > Thanks a lot! > Jason Cai > > > DEFINE GDG (NAME(DBJMP05.FAS.SE.FMLX.HIST) - > >LIMIT(03)

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread ibmnew
Our shop is z/OS 1.11. the image is a single image. Thanks a lot! Hi all Our shop is RACF. It is single level alias DBJMP05.BDZ3.MAN1 catalog to the same catalog as the GDG. Thanks a lot! Jason Cai > DEFINE GDG (NAME(DBJMP05.FAS.SE.FMLX.HIST) - >LIMIT(03)

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread ibmnew
Hi all Our shop is RACF. It is single level alias DBJMP05.BDZ3.MAN1 catalog to the same catalog as the GDG. Thanks a lot! Jason Cai > DEFINE GDG (NAME(DBJMP05.FAS.SE.FMLX.HIST) - >LIMIT(03) - >NOEMPTY

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Lizette Koehler
> DEFINE GDG (NAME(DBJMP05.FAS.SE.FMLX.HIST) - >LIMIT(03) - >NOEMPTY- >SCRATCH ) > > The return is 12 > > ICH408I USER(DBJMP05

Re: What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread Hunkeler Peter (KIUP 4)
>ICH408I USER(DBJMP05 ) GROUP(#TMPUG ) NAME(APPL MAINTENANCE > CATALOG.PLEXBDZ3.TSO CL(DATASET ) VOL(BD3CT1) > INSUFFICIENT ACCESS AUTHORITY > FROM CATALOG.PLEXBDZ3.TSO (G) > ACCESS INTENT(UPDATE ) ACCESS ALLOWED(READ )

What is the difference of the entry of the GDG vs VSAM in CATALOG

2011-03-03 Thread ibmnew
Hi all We defined a VSAM file and a GDG base using a user id DBJMP05. The prefix of DBJMP05 is managed by SMS SMS routing SC : FILTLIST TSOUSERS INCLUDE(DBJMP*) WHEN &HLQ = &TSOUSERS SET &STORCLAS = 'SCSTAND' SG: FILTLIST TSOUSERS INCLUDE