Production Mainframe Issue - Urgent

2008-03-07 Thread Jacky Bright
Hi Does the message *IEE806A COMMANDS EXCEED LIMIT IN COMMAND CLASS M3 can cause system to halt ? JAcky -- Forwarded message -- From: Jacky Bright [EMAIL PROTECTED] Date: Mar 6, 2008 3:31 PM Subject: Production Mainframe Issue - Urgent To: IBM Mainframe Discussion List IBM

Re: Production Mainframe Issue - Urgent

2008-03-07 Thread Barbara Nitz
Does the message *IEE806A COMMANDS EXCEED LIMIT IN COMMAND CLASS M3 can cause system to halt ? No. Commands do not get executed anymore until the 100 queued commands are executed. Use the CMDS command to display the command that are hung and check *why* they are hung. This command was

Re: Production Mainframe Issue - Urgent

2008-03-06 Thread Elardus Engelbrecht
Jacky Bright wrote: 1) Following messages in syslog for around 3-4 min. EMS0518E MODULE EMSCLOGC; ERROR DURING LOGON ERROR CODE = X01 LU = TCP03025. EMS0430E EMSCSYND FAILED, RC = 99. EMS0518E MODULE EMSCLOGC; ERROR DURING LOGON ERROR CODE = X02 LU = TCP03025. EMS0518E MODULE EMSCLOGC; ERROR

Production Mainframe Issue - Urgent

2008-03-06 Thread Jacky Bright
Hi, Today my team observed unusual thing. PSG group started getting calls that all mainframe apps are not working. On analysing the logs there were 2 - 3 issues 1) Following messages in syslog for around 3-4 min. EMS0518E MODULE EMSCLOGC; ERROR DURING LOGON ERROR CODE = X01 LU = TCP03025.