To answer Jake's original question, CBU can be deactivated at any time by
command (either in z/OS, on HMC/SE, or by API, depending on your hardware
model). That stops the licensing accrual for CBU (as well as limiting the
MSU back to non-CBU value). Several ways to do it, the simplest is to vary
On Sun, 5 Dec 2021 00:46:34 +, Seymour J Metz wrote:
>Isn't a real DR usually temporary?
>
>
>--
>Shmuel (Seymour J.) Metz
>http://mason.gmu.edu/~smetz3
>
CBU Test last only for 10 days whereas a CBU for an actual DR can last for up
to 90 days...
Roger
Isn't a real DR usually temporary?
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of
Stuart Holland [stuartz...@outlook.com]
Sent: Saturday, December 4, 2021 5:56 PM
To:
That happened to us once (person replied that it was a real DR instead
of a test). We contacted IBM right away and they fixed the CBU settings
and didn't charge us.
On 12/4/2021 6:41 AM, Jake Anderson wrote:
Hello
Is it possible to swtich back to temporary CBU activation incase it someone
W dniu 04.12.2021 o 13:41, Jake Anderson pisze:
Hello
Is it possible to swtich back to temporary CBU activation incase it someone
has activated the CBU permanently by mistake ?
There are two modes of CBU Test and Real Activation.
Test can be switched back at any time you want or it will be
On Sat, 4 Dec 2021 15:22:29 +, Colin Paice wrote:
>
>I would be happy with some better doc ( I'll raise another RCF), explaining
>what happens.
>
No.
>The buglet that needs fixing is
>
Yes.
>// set A=''
>// EXEC PGM,PARM='Z Y'
>the parameter passed to the program is 'Z' I would expect
Peter,
You raise an interesting question about the “what should we do” thing to do.
In my experience, whether in software or not, the best course of action is
always to do the right thing, the “what should we do”.
Every single time I take another course of action, it turns out to be a false
Peter,
I would be happy with some better doc ( I'll raise another RCF), explaining
what happens.
The buglet that needs fixing is
// set A=''
// EXEC PGM,PARM='Z Y'
the parameter passed to the program is 'Z' I would expect either 'Z Y'
or 'Z Y '
real example
//IHS EXEC
I agree that it is counter-intuitive (and unfriendly) that, for proc
symbol yyy, you can do
SET xxx=
but that
SET xxx='' or even SET xxx='' (if a trailing period were
necessary to clearly identify a symbol's usage) do not do what you'd
expect.
Specifically, it appears that the substitution
Check with IBM in any case. You'll need their involvement.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Jake Anderson
Sent: Saturday, December 4, 2021 7:41 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: CBU HMC activation - switching back
Hello
Is it possible to
Hello
Is it possible to swtich back to temporary CBU activation incase it someone
has activated the CBU permanently by mistake ?
Jake
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
11 matches
Mail list logo