Hi Skip,

Any scars from not doing so?

– Vignesh
Mainframe Infrastructure

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Jesse 1 Robinson
Sent: Saturday 19-May-2018 03:17
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: RACF on a Sysplex??

One sort of obvious point. Before cloning your RACF data base make sure that 
*all* data set profiles are generic. Convert any that are not.

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
robin...@sce.com


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Mark Zelden
Sent: Thursday, May 03, 2018 3:45 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: (External):Re: RACF on a Sysplex??

My client has a mixture of things, but nothing is ever shared with a sandbox 
LPAR - not even
via RRSF "one way".   It really doesn't seem dangerous to do it one way, but I 
still
prefer to isolate things in a sandbox as completely as possible.

One business unit with 2 large sysplexes has separate RACF databases, but RRSF 
keeps things in sync.  Both have sysplex communications enabled in the DSNT and 
CF structures.

Another business unit has one RACF database shared between 2 sysplexes.  MII is 
the integrity manager and SYSZRACF is excluded, so the DB is protected with 
RESERVEs.

Another business unit has a 2 system basic sysplex and is in GRS ring mode, 
RACF DB is shared between both.  I just checked and SYSZRACF is converted to a 
global ENQ.

Another business unit has a prod / devl LPAR (both monoplexes).  They share a 
RACF
DB.  Since there is no GRS ring, the DB is protected with RESERVE.   There is a 
sandbox
version of this business unit also, but it has its own RACF DB.

There are also 2 sandbox parallel sysplexes each with 2 LPARs that are "clones" 
of the first 2 environments I wrote about - one with GRS, the other with MII. 
Both those sysplexes have their own RACF DBs, have sysplex communications 
enabled in the DSNT
and CF structures.

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 
Foundation Certified mailto:m...@mzelden.com Mark's MVS Utilities: 
http://www.mzelden.com/mvsutil.html
Systems Programming expert at http://search390.techtarget.com/ateExperts/


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

MARKSANDSPENCER.COM
________________________________
 Unless otherwise stated above:
Marks and Spencer plc
Registered Office:
Waterside House
35 North Wharf Road
London
W2 1NW

Registered No. 214436 in England and Wales.

Telephone (020) 7935 4422
Facsimile (020) 7487 2670

www.marksandspencer.com

Please note that electronic mail may be monitored.

This e-mail is confidential. If you received it by mistake, please let us know 
and then delete it from your system; you should not copy, disclose, or 
distribute its contents to anyone nor act in reliance on this e-mail, as this 
is prohibited and may be unlawful.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to