Anyone besides me remember this? I did report it to IBM, and I have been running SLIPs and dumps off and on for the past five+ months for LE Level two. They have now figured it out!
https://www-304.ibm.com/support/entdocview.wss?uid=isg1PM68947 Charles -----Original Message----- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Don Poitras Sent: Wednesday, February 01, 2012 10:25 AM To: ibm-m...@bama.ua.edu Subject: Re: S0C4 in CEE3DMP Then you should open a PMR with IBM. They have two problems to solve: 1. An abend in CEE3DMP 2. Incorrect diagnotic message In article <01f001cce108$66577f60$33067e20$@mcn.org> you wrote: > It's not blowing up in SignalHandler.C; it is blowing up IN CEE3DMP: I get > half of the CEE3DMP output and no "I'm all done" message. > Charles > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf > Of Don Poitras > Sent: Tuesday, January 31, 2012 8:18 PM > To: ibm-m...@bama.ua.edu > Subject: Re: S0C4 in CEE3DMP > Tea leaves are good for making tea. :) I would compile SignalHandler.C with > the LIST option to see the psuedo assembly output and see from the dump > where the abend occured and try to figure out what went wrong. The message > you've given wouldn't lead me to think there was a problem in CEEDMP, but > rather in the calling code. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN