Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Lizette Koehler
Sent: Friday, November 11, 2016 7:29 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: SVC display
From the manual: z/OS z/OS 2.1.0 z/OS MVS z/OS MVS Diagnosis:
Reference
>I would like to know if there is any question to view SVC in use if it is
added dynamically ?
Locating a "module" in some system data set will not in general indicate
if an SVC is "in use" (imagine if the module was added after the IPL
completed) although for "normal" things, during IPL, the
TASID (written by Doug Nadel when he was in ISPF support I think) will provide
this SVC information along with other sysprog "stuff". It is available on the
IBM tools website on an asis basis.
http://www-01.ibm.com/support/docview.wss?uid=swg24009131
Andrew
From the manual: z/OS z/OS 2.1.0 z/OS MVS z/OS MVS Diagnosis:
Reference System Reference SVC summary SVC routines Naming
conventions for SVC routinee
Naming conventions for SVC routines
SVC routines are load modules which are named as follows:
The routines
[Default] On 11 Nov 2016 09:45:36 -0800, in bit.listserv.ibm-main
bill.wood...@gmail.com (Bill Woodger) wrote:
>"(The last letter is in packed decimal x'c1' in this case.) "
>
>Not sure what you mean by that. x'c1' isn't packed-decimal.
X'1C' would be packed decimal. X'C1' is zoned decimal. The
"(The last letter is in packed decimal x'c1' in this case.) "
Not sure what you mean by that. x'c1' isn't packed-decimal.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu
' in this case.)
HTH,
Lindy
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Jake Anderson
Sent: maanantaina 7. marraskuuta 2016 12.05
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: SVC display
Hi
Apology in advance this might be a repetitive questions
Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
> > Behalf Of Jake Anderson
> > Sent: Monday, November 07, 2016 3:05 AM
> > To: IBM-MAIN@LISTSERV.UA.EDU
> > Subject: SVC display
> >
> > Hi
> >
> > Apology in advance this might be a rep
/Omegamon/SYSVIEW, etc..
What problem are you trying to solve?
Lizette
> -Original Message-
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
> Behalf Of Jake Anderson
> Sent: Monday, November 07, 2016 3:05 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Su
I do not understand the question.
What are you trying and what is happening?
On Mon, 7 Nov 2016 15:34:58 +0530 Jake Anderson
wrote:
:>Apology in advance this might be a repetitive questions
:>I would like to know if there is any question to view SVC in use if it is
Jake Anderson wrote:
>I would like to know if there is any question to view SVC in use if it is
>added dynamically ?
You can list SVC as loaded using SHOWMVS. But there are other utilities
available to do that same thing as long they're assembled as AC(1) of course.
It depends on your
Hi
Apology in advance this might be a repetitive questions
I would like to know if there is any question to view SVC in use if it is
added dynamically ?
Any pointers would be much appreciated.
Jake
--
For IBM-MAIN subscribe /
12 matches
Mail list logo