Maybe you have no hardware :-(
Seriously, sounds APARable. Imagine this fun during a production emergency
IPL!
On Tue, Oct 30, 2012 at 5:42 AM, R.S. r.skoru...@bremultibank.com.plwrote:
The following scenario
An LPAR with z/OS.
The z/OS is shut down (Z EOD).
After that, a LOAD is
Well, I do have hardware and I do have a problem (actually I found
walk-around - LPAR re-Activation).
I'm not sure wheher it's APARable, since no z/OS software is started yet
when the error occurs.
Regards
--
Radoslaw Skorupka
Lodz, Poland
W dniu 2012-10-30 16:43, zMan pisze:
Maybe
The only thing I can think of is that the RESET does clear any channel
status that would cause a conflict. Since IPL Text is at the other end of
a channel.. maybe that is the issue.
After shutting down a system, we always performed a RESET. Got burned a
few times with channels that caused
? So the HMC isn't a component? Sure it is...
On Tue, Oct 30, 2012 at 11:59 AM, R.S. r.skoru...@bremultibank.com.plwrote:
Well, I do have hardware and I do have a problem (actually I found
walk-around - LPAR re-Activation).
I'm not sure wheher it's APARable, since no z/OS software is started
Hardware / License Internal Code / ESC hardware service call.
On Tue, Oct 30, 2012 at 1:32 PM, zMan zedgarhoo...@gmail.com wrote:
? So the HMC isn't a component? Sure it is...
On Tue, Oct 30, 2012 at 11:59 AM, R.S. r.skoru...@bremultibank.com.plwrote:
Well, I do have hardware and I do have a
Correct. I don't know how R.S. does it in Poland, but in the US I would call the
service number and open a PMH (hardware PMR).I've done it on more
than a couple of occasions.There are all sorts of lpar dumps and transmits
of various log data that can be done from the SE and that hopefully
W dniu 2012-10-30 21:26, Mark Zelden pisze:
Correct. I don't know how R.S. does it in Poland, but in the US I would call the
service number and open a PMH (hardware PMR).I've done it on more
than a couple of occasions.There are all sorts of lpar dumps and transmits
of various log data