Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of nitz-...@gmx.net
Sent: Monday, December 17, 2012 06:34
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: replacing system logger cds with a smaller dataset
I would like to replace the system logger cds with a smaller dataset
Hi,
I would like to replace the system logger cds with a smaller dataset.
When I try to do this I get:
SETXCF COUPLE,TYPE=LOGR,ACOUPLE=(SYS1.LOGR.CDS03)
IXC309I SETXCF COUPLE,ACOUPLE REQUEST FOR LOGR WAS ACCEPTED
IXC260I ALTERNATE COUPLE DATA SET REQUEST FROM SYSTEM 028
CDVL FOR LOGR IS NOW
I would like to replace the system logger cds with a smaller dataset.
Is it possible to force the use of the smaller data set?
Not dynamically, no.
You will have to format new LOGR CDSs at the desired size, change COUPLExx to
point to the new datasets and reIPL the sysplex, thus cold-starting
Thanks
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of nitz-...@gmx.net
Sent: Monday, December 17, 2012 7:34 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: replacing system logger cds with a smaller dataset
I would like to replace