Re: replacing system logger cds with a smaller dataset

2012-12-17 Thread Vernooij, CP - SPLXM
Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of nitz-...@gmx.net Sent: Monday, December 17, 2012 06:34 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: replacing system logger cds with a smaller dataset I would like to replace the system logger cds with a smaller dataset

replacing system logger cds with a smaller dataset

2012-12-16 Thread גדי בן אבי
Hi, I would like to replace the system logger cds with a smaller dataset. When I try to do this I get: SETXCF COUPLE,TYPE=LOGR,ACOUPLE=(SYS1.LOGR.CDS03) IXC309I SETXCF COUPLE,ACOUPLE REQUEST FOR LOGR WAS ACCEPTED IXC260I ALTERNATE COUPLE DATA SET REQUEST FROM SYSTEM 028 CDVL FOR LOGR IS NOW

Re: replacing system logger cds with a smaller dataset

2012-12-16 Thread nitz-...@gmx.net
I would like to replace the system logger cds with a smaller dataset. Is it possible to force the use of the smaller data set? Not dynamically, no. You will have to format new LOGR CDSs at the desired size, change COUPLExx to point to the new datasets and reIPL the sysplex, thus cold-starting

Re: replacing system logger cds with a smaller dataset

2012-12-16 Thread גדי בן אבי
Thanks -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of nitz-...@gmx.net Sent: Monday, December 17, 2012 7:34 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: replacing system logger cds with a smaller dataset I would like to replace