I was recently contacted by one company who was starting a project to throw
out thousands of assembler language programs and replace them with JAVA
code all with the aim of modernising his mainframe. The interview went
badly when I asked why he thought he had to discard years of development
which
Must have missed this.
> I'll be honest - it's getting smaller and smaller. It's become a niche,
> mainly for system tools ISVs. Metal C is where the invisible hand of IBM is
> pushing the industry.
And Ray is one of the most respected in the field.
Sent from Yahoo Mail for iPhone
On
Very little from what I see. What little
there is is stupid stuff like reverse engineering code so that the client
can rewrite it in JAVA or whatever the language of the day is.
On Tue, Sep 5, 2023, 6:48 AM Bill Johnson <
0047540adefe-dmarc-requ...@listserv.ua.edu> wrote:
> How much demand
You have to logon as an administrator. Select HMC Management, followed by the
Create Welcome Text option.
Lastly, if you put something in the Classification box, that will be the
background for the Welcome screen.
Sent with Proton Mail secure email.
--- Original Message ---
On
One of my P/390s has the bus and tag hardware and a 3174-11L connected.
(Well, technically they're R/390s and RS/370s, but still...) I also have a
3174-63R talking via Token Ring.
On Tue, Sep 5, 2023 at 9:10 AM Grant Taylor <
023065957af1-dmarc-requ...@listserv.ua.edu> wrote:
> On 9/5/23
Never seen an option to do thatwhere is it?
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
rpinion865
Sent: Tuesday, September 5, 2023 3:08 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: HMC Splash screen
Never mind we found where to change it!
Sent with
On 9/5/23 8:56 AM, Jay Maynard wrote:
I do! And two P/390s and two P/370s for it to talk to.
Does that mean that you also have the associated B cards to connect
said P/390s / P370s to the 3174?
I'd be very interested reading an article about and pictures of such a
setup. Even if it's an
Never mind we found where to change it!
Sent with Proton Mail secure email.
--- Original Message ---
On Tuesday, September 5th, 2023 at 9:42 AM, rpinion865
<042a019916dd-dmarc-requ...@listserv.ua.edu> wrote:
> We would like to change the DR HMC splash screen. How can this be
I also think that what many of us seem to forget is that skills need to
be used to stay sharp and to learn new things in that field.
If you are not doing Assembler a fair amount of time, the skill dulls.
Some of the worse assembler I have ever seen was written by people who
had not written it
I do! And two P/390s and two P/370s for it to talk to.
On Tue, Sep 5, 2023 at 8:53 AM Mike Shaw wrote:
> Jay,
>
> Have you got a 3174 also?
>
> I wrote code in 1981 that invoked GDDM/PGF to write to 3279s. It was fun to
> see it display pie charts, bar graphs, etc. Very cool for the times.
>
>
Jay,
Have you got a 3174 also?
I wrote code in 1981 that invoked GDDM/PGF to write to 3279s. It was fun to
see it display pie charts, bar graphs, etc. Very cool for the times.
Mike Shaw
MVS/QuickRef Support Group
Chicago-Soft, Ltd.
Thanx. I know I can use this.
Steve Thompson
On 9/5/2023 9:14 AM, Lionel B. Dyck wrote:
Just ran across this - y'all (or some) may be interested:
Free Zowe course and OMP digital badge from Interskill and the Open
Mainframe Project. Enjoy!
https://interskill.com/zowe/
Lionel B. Dyck <><
How much demand is there for IBM mainframe Assembler programmers?
Ray Mullin said this:
I'll be honest - it's getting smaller and smaller. It's become a niche, mainly
for system tools ISVs. Metal C is where the invisible hand of IBM is pushing
the industry.
Having said that…
We would like to change the DR HMC splash screen. How can this be done?
Sent with [Proton Mail](https://proton.me/) secure email.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
Thanks
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Lionel B. Dyck
Sent: יום ג 05 ספטמבר 2023 16:14
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Free ZOWE Class
Just ran across this - y'all (or some) may be interested:
Free Zowe course and OMP digital badge from
Yes, we send a bug report way back in the 1960's at Shell Oil in Melbourne.
We used COND codes a lot, and it mucked everything up!
Clem
Colin Paice wrote:
I heard that IEFBR14 had the highest "bug rate" per line of code
1) There was no CSECT statement
2) It was not reentrant
3) It did not
Just ran across this - y'all (or some) may be interested:
Free Zowe course and OMP digital badge from Interskill and the Open
Mainframe Project. Enjoy!
https://interskill.com/zowe/
Lionel B. Dyck <><
Website: https://www.lbdsoftware.com
Github: https://github.com/lbdyck
Worry more about
I heard that IEFBR14 had the highest "bug rate" per line of code
1) There was no CSECT statement
2) It was not reentrant
3) It did not clear R15 prior to exit
4) It was missing an end statement
I was told this over 40 years ago... and may not be true
On Tue, 5 Sept 2023 at 13:53, Bob Bridges
Please do not use this subject heading,
Please change it to what you are talking about.
On 2023-09-05 22:53, Bob Bridges wrote:
Hey, look at that! I never knew why the famous IEFBR14 was so named;
now I guess maybe I do, though I won't be guessing after I look up the
BR instruction).
Hey, look at that! I never knew why the famous IEFBR14 was so named; now I
guess maybe I do, though I won't be guessing after I look up the BR
instruction).
---
Bob Bridges, robhbrid...@gmail.com, cell 336 382-7313
/* The historic case against miracles...consists of calling miracles
Classification: Confidential
SMF type 17 records
I strongly suggest the DAF program form the CBT tape.
HTH,
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Sathish Kumar
Sent: Monday, September 4, 2023 9:59 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: SMF Extract Using
And “100% busy” is the wrong criterion – if you want your system to be
performant.
Cheers, Martin
From: IBM Mainframe Discussion List on behalf of
Peter Relson
Date: Tuesday, 5 September 2023 at 13:13
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: Switching between SMT-1 and SMT-2
Remind me, Scott (or anybody): Does switching modes cause a WLM reset? Might
not be something you want to do throughout the day – if so.
Thanks, Martin
From: IBM Mainframe Discussion List on behalf of
Scott Chapman <03fffd029d68-dmarc-requ...@listserv.ua.edu>
Date: Tuesday, 5 September
The current situation sounds like SMT-2 should only be used if you
a) have a single zIIP
or b) are running your zIIPs consistently 100% busy
and for b) you need to turn it off when the workload reduces?
I don't think that that is a correct conclusion. It is far more complicated
than thinking
Peter
My fault the code is great didn’t remembet having a sysstate ascenv=AR most
macros
Don’t take you out of AR and back they just say you cannt use it in AR
Thank you
> On Sep 4, 2023, at 11:39 PM, Joseph Reichman wrote:
>
> I don’t know if used sysstate macro but let me check i
Joe R wrote
Can someone explain to me why the last instruction in the LOCASCB MACRO is
SAC X'200'
Because one of the first instructions is SAC 0 and you told LOCASCB via
SYSSTATE that you are in AR-mode and LOCASCB does not run in AR mode, so it
switched out of AR mode before branching to the
Ed
Thanks you are correct was in bed when I saw the email
Just looked at the code had ASCENV=AR
> On Sep 4, 2023, at 11:39 PM, Joseph Reichman wrote:
>
> I don’t know if used sysstate macro but let me check i would assume the
> default value is primary
>
>>> On Sep 4, 2023, at 11:33 PM,
I drove 1800 miles over the long weekend, and now own a real live
honest-to-goodness 3279 terminal. It's in somewhat rough shape, and in
particular is missing the front bezel entirely. Does anyone around here
know where I might be able to find one? The 3279 is pretty rare these days,
so I won't be
It's more complicated than that. Although I would agree that if an LPAR has
only a single zIIP, likely SMT would be a good idea. But B is not true for
intervals that people usually consider when looking at utilization levels
because at the level of dispatch intervals, it's much more likely
Personal attacks are really not warranted. I think we can discuss our systems
programming beliefs without attacking someone.
Brian
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
Equating college and systems programming is not really logical. I'm not aware
of any colleges that "teach" how to be a systems programmer. I think some may
have tried, but I doubt it would be a big draw.
I have a PhD, but I didn't learn to write assembler in college, at least not
any that
update
I should add to AUTHTSF another name: HWIC1TRX
Now it works... well... it still doesn't work, but it is no longer 3841
return code. :-)
--
Radoslaw Skorupka
Lodz, Poland
W dniu 05.09.2023 o 10:25, Gadi Ben-Avi pisze:
Try adding the program to the AUTHTSF section of IKJPRMxx.
Gadi
Did you run the TSO PARMLIB command (or mvs set)?
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
Well, I just tried and still same error code.
--
Radoslaw Skorupka
Lodz, Poland
W dniu 05.09.2023 o 10:25, Gadi Ben-Avi pisze:
Try adding the program to the AUTHTSF section of IKJPRMxx.
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Radoslaw Skorupka
Try adding the program to the AUTHTSF section of IKJPRMxx.
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Radoslaw Skorupka
Sent: יום ג 05 ספטמבר 2023 11:22
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: BCPii retcode 3841
I'm trying to run a sample from the manual,
If you are truly interested in learning System z assembler, then one resource
you could use is the late John Ehrman's book 'Assembler Programming for IBM
System z Servers' - a quick google search should find it for you.
The reason I am posting this is to mention some macros detailed in
I'm trying to run a sample from the manual, nothing sophisticated:
ListType= HWI_LIST_CPCS;
Address BCPII "HWILIST retcode ConnectionToken ListType AnswerArea.
DiagArea."
and I get retcode = F01 (3841 dec).
The manual say HWI_AUTH_FAILURE, the program does not reside in
APF-authorized
101 - 137 of 137 matches