Hi Gadi,
We had this issue once a while back when moving ARCHLOG2 to virtual tape.
The SMS rules were changed to direct the archlog2 files to the virtual tape,
but the UNIT2 parm
in DSN6ARVP was still set to SYSDA. Once UNIT2 was set to the correct value,
we no longer
had the problem.
, July 10, 2019 9:15 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Writing DB2 Archlog to tape
No,
Unit=work is not correct
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Neubert, Kevin
Sent: Wednesday, July 10, 2019 11:58 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re
, 2019 9:15 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Writing DB2 Archlog to tape
No,
Unit=work is not correct
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Neubert, Kevin
Sent: Wednesday, July 10, 2019 11:58 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re
No,
Unit=work is not correct
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Neubert, Kevin
Sent: Wednesday, July 10, 2019 11:58 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Writing DB2 Archlog to tape
DB2P.ARCHLOG2.B0003034 and DB2P.ARCHLOG2.A0003034 should
DB2P.ARCHLOG2.B0003034 and DB2P.ARCHLOG2.A0003034 should be one tape. The
prior is the BSDS copy and latter is the archive log.
In the DSNJ003I message associated with DB2P.ARCHLOG2.A0003034 is UNIT=WORK
correct? Do you see a catalog entry for DB2P.ARCHLOG2.A0003034 related to disk?
Regards,
Gadi,
I'm not sure where to look because somebody else set it up here, but what
you're trying to do is definitely doable - because that's how it is set up
here. Second copy of archlogs go to a tape and "filea" is label 1 on the tape
and "fileb" is label 2, both cataloged.
Rex
-Original
As far as I know, it was changed.
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Bill Bishop (TMNA)
Sent: Wednesday, July 10, 2019 4:09 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Writing DB2 Archlog to tape
Does DSNZPARM for the DB2 system need to be changed
Does DSNZPARM for the DB2 system need to be changed to reflect the unit type
and other information?
Thanks
Bill Bishop
Consultant, Mainframe Engineer
Mainframe and Scheduling | Infrastructure Technology Services
Toyota Motor North America
bill.bis...@toyota.com
Office: (469) 292-5149
Cell: