Thanks for the help.
Jim
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Nick Jones
Sent: Sunday, June 23, 2013 5:25 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Need to move some DASD volumes that have system logger datasets on
From a logger perspective there is no clear answer, but there are a number of
tools to get off the data set.
Logger data sets are of the form HLQ.lsname.suffix and there are staging data
sets and offload data sets.
To get off of staging data sets you can change the duplex method for the log
Or FDRPAS?
And you can license both products to move a specific amount of TBs.
Kees.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Lizette Koehler
Sent: Friday, June 21, 2013 03:39
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Need to
Hi,
TDMF is the best i would suggest as it handles ENQ very well. We
replaced EMC box with DS8800 last year , used TDMF and moved even
couple and page volumes successfully .
Regards,
Baby
On 6/21/13, Vernooij, CP - SPLXM kees.verno...@klm.com wrote:
Or FDRPAS?
And you can license both
TDMF and FDRPAS are equal in moving data reliably. When we moved our
ESSs to DS8800, we got no recommendation that favored one over the
other.
You don't move data and handle their ENQs rather good or not so good,
you only do it good of bad.
Kees.
-Original Message-
From: IBM Mainframe
may be you are right . I never worked on FDRPAS and doesn't know much
abt it . I felt TDMF was pretty simple and easy to use . Thanks !
Regards,
Baby
On 6/21/13, Vernooij, CP - SPLXM kees.verno...@klm.com wrote:
TDMF and FDRPAS are equal in moving data reliably. When we moved our
ESSs to
No we don't have either TDMF or FDRPAS. I've moved most of the array by doing
full volume copies durring down time, but I've got a few left that are
allocated to some basic system stuff.
Thanks for the suggestions.
Jim
-Original Message-
From: IBM Mainframe Discussion List
Have a DASD box that is being retired and I have some volumes on it that have
datasets allocated to the sysplex logger task. I need some way of removing the
dataset from the logger task to I can DFDSS volume copy the devices to the
replacement box keeping the dataset and volser the same.
Any
Yes, stop what is using them:
D LOGGER,CONN,LSN=*,D
Regards,
Leonardo Vaz
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Darby, Jim
Sent: Thursday, June 20, 2013 4:42 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Need to move some DASD
Do you have TDMF?
Lizette
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Darby, Jim
Sent: Thursday, June 20, 2013 1:42 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Need to move some DASD volumes that have system logger datasets on
10 matches
Mail list logo