I suggest APPLY CHECK SOURCID(RSU1905 RSU1906).
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Bill Giannelli
Sent: Sunday, July 28, 2019 9:37 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: "merging" 2 RSU levels
Thank you both for your responses!
I can se
Thank you both for your responses!
I can see now when I receive RSU1906 it only shows the holddata for the sysmods
not ye received, which is what I wanted.
Got it now!
thanks
Bill
--
For IBM-MAIN subscribe / signoff / archive
No it won't. You're just requesting a check for RSU1906, not RSU1905. I'd also
modify your command to this, APPLY CHECK SOURCEID(RSU1906) GROUPEXTEND
BYPASS(HOLDSYSTEM).
Mark Jacobs
Sent from ProtonMail, Swiss-based encrypted email.
GPG Public Key -
thanks for your response.
but if I run apply check for rsu1906, wont that give ALL the holddata, and not
the difference between RSU1905 and RSU1906?
thanks
Bill
--
For IBM-MAIN subscribe / signoff / archive access instructions,
On Sun, 28 Jul 2019 06:25:32 -0500, Bill Giannelli
wrote:
>If I have RSU1905 received and Apply checked and prepared the holddata actions
>ready to go, but now want to receive and apply rsu1906; should I first
>implement rsu1905 then apply rsu1906? how do I only get the additional
>holddata?
If I have RSU1905 received and Apply checked and prepared the holddata actions
ready to go, but now want to receive and apply rsu1906; should I first
implement rsu1905 then apply rsu1906? how do I only get the additional
holddata? I just want to get the additional actions I need for the extra