Tom, you were correct on the EXPORT DISCONNECT/IMPORT CONNECT to the new master
(which was a usercat to the current master. I then used RCNVCAT to generate
the ALIAS statements.
The DEL UCAT NODISCONNECT/DEF UCAT RECONNECT was not applicable for this, but
is of value for moving a usercatalog. Just had to follow your good advice and
RTFM to drill down.
Thanks for responding!
David
-Original Message-
From: Tom Marchant <000a2a8c2020-dmarc-requ...@listserv.ua.edu>
To: IBM-MAIN <IBM-MAIN@LISTSERV.UA.EDU>
Sent: Mon, Feb 26, 2018 4:27 pm
Subject: Re: IDCAMS NODISCONNECT
On Mon, 26 Feb 2018 09:06:48 -0600, Tom Marchant wrote:
>On Mon, 26 Feb 2018 08:41:18 -0600, David Purdy wrote:
>
>>After I created a new master, another sysprog successfully moved a UCAT to a
>>different and larger volume. My goal is to correct my new master catalog
>>without affecting the heavily used production UCAT and defined ALIAS.
>
>I would do EXPORT DISCONNECT from the new master, followed by IMPORT CONNECT.
Or just IMPORT CONNECT ALIAS to preserve the alias information in the new
master catalog.
--
Tom Marchant
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN