Re: SMPe holddata for previous apply run

2020-09-16 Thread Seymour J Metz
It's not clear what you're asking. There have been two answers to possible interpretations of the question, both appropriate. By "moved", do you mean copying an entire target and target zone, or copying libraries without copying the target zone recording their status? -- Shmuel (Seymour J.)

Re: SMPe holddata for previous apply run

2020-09-16 Thread Kurt Quackenbush
On 9/16/2020 9:17 AM, Bill Giannelli wrote: I have applied a round of maintenance a few months back but havent moved it into our "run time libraries" yet. Is there a way to run a SMPe report and get the HOLDDATA from that previous APPLY? Are you talking about the SYSTEM HOLDs that describe the

Re: SMPe holddata for previous apply run

2020-09-16 Thread Paul Gilmartin
On Wed, 16 Sep 2020 08:17:11 -0500, Bill Giannelli wrote: >I have applied a round of maintenance a few months back but havent moved it >into our "run time libraries" yet. Is there a way to run a SMPe report and get >the HOLDDATA from that previous APPLY? > REPORT ERRSYSMODS? -- gil

Re: SMPe holddata for previous apply run

2020-09-16 Thread David Spiegel
Hi Bill, Add CHECK and REDO. Regards, David On 2020-09-16 09:17, Bill Giannelli wrote: I have applied a round of maintenance a few months back but havent moved it into our "run time libraries" yet. Is there a way to run a SMPe report and get the HOLDDATA from that previous APPLY? thanks Bill