[Ifeffit] Br K-edge exafs spectrum of NaBr(s) or KBr(s)

2009-10-08 Thread Gleb Pokrovski
Hello, I'm looking for a good exafs spectrum in transmission mode at Br K-edge of NaBr or KBr solids at ambient or low-temperature conditions. Any help will be referenced and acknowledged. Thanks in advance Gleb ___ Ifeffit mailing list

Re: [Ifeffit] First shell resolution

2009-10-08 Thread Bruce Ravel
On Thursday 08 October 2009 01:00:54 am Eugenio Otal wrote: Hello, I have a very noisy signal so I have a relative good signal until k =9. I am trying to fit the first shell and want to know if there are a limit for the subshells resolution if the signal is unavailable for k larger than 9.

[Ifeffit] Fwd: Mg k-edge and Athena Questions

2009-10-08 Thread Bruce Ravel
I am forwarding this message to the Ifeffit mailing list, which is the proper forum for Ifeffit software support. Please see http://cars9.uchicago.edu/iffwiki/BruceRavel/FormLetters/HelpRequest I have some comments, which I will post once this gets distributed by the mailing list.

Re: [Ifeffit] Fwd: Mg k-edge and Athena Questions

2009-10-08 Thread Bruce Ravel
On Thursday 08 October 2009 08:47:11 am Bruce Ravel wrote: This is Fang from Yale University, Pfefferle and Haller's group. Besides our research on Co/Pt on your X23A2 and X18B, I am mainly involved in the Mg and B edge measurement. I heard from Paul that you also have anongoing project on Mg

Re: [Ifeffit] Fwd: Mg k-edge and Athena Questions

2009-10-08 Thread MacLean, Lachlan
I believe the SGM beamline (11ID-1) at the Canadian Light Source also works in this energy range. http://www.lightsource.ca/experimental/sgm.php Lachlan -- Lachlan C.W. MacLean Canadian Government Postdoctoral Fellow Health Canada - Safe Environments Programme

Re: [Ifeffit] Fwd: Mg k-edge and Athena Questions

2009-10-08 Thread Jason Gaudet
The Photon Factory at KEK, Tsukuba, Japan has two beamlines (BL7A, BL2C) that cover 250-1500 eV at around 10^9 photons/s. Bruce Ravel wrote: There are some other options if you are willing to look farther afield than NSLS. The XAS beamline at CAMD is one option. I believe that there are

Re: [Ifeffit] Fwd: Mg k-edge and Athena Questions

2009-10-08 Thread Jeff Terry
Beamline 3-3 at SSRL was very good in this range. I made Mg K-edge XAFS measurements there many times. I do not know if this is one of the beamlines that was shuttered during the SSRL upgrade though. There is also a chance that the Double Crystal Monochromator beamline at the SRC could make