Hello;
Trying to plot a fit in Artemis.
My .dat files appear flat on y= zero in the plot window.
they open fine in Athena.
Any help would be appreciated.
regards
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
plots parameters, options are the same for Artemis and Athena?
regards
W dniu 11-08-03 08:23, Morgan Scott pisze:
Hello;
Trying to plot a fit in Artemis.
My .dat files appear flat on y= zero in the plot window.
they open fine in Athena.
Any help would be appreciated.
regards
LinkedIn
ifeffit,
I'd like to add you to my professional network on LinkedIn.
- Somaditya
Somaditya Sen
Research Associate at Physics Dept., UWM
Greater Milwaukee Area
Confirm that you know Somaditya Sen
https://www.linkedin.com/e/o6ijfu-gqwaay89-k/isd/3744123338/3Yn0HeKq/
Dear All,
I acquired Cd L3-edge spectra of some binary and ternary mixtures in
varying proportions and for the individual components. Then, I tried
to fit the reference spectra to the spectra of the mixtures using
linear combination fitting of Athena to get their abundance. However,
Paul, have you considered explicitly multiple scattering from within the
tetrahedron? The short distance you describe for the second shell might
be consistent with that.
Its pretty easy to write an expression in the fit routine that makes the
MS path distances explicitly dependent on the SS
Hi Paul,
Looking at your data, I agree that there does seem to be second-shell
scattering present in the signal.
Unfortunately, that most likely means that your material is not close
to one of the obvious model compounds. One possibility to keep in
mind is that you may have some kind of
Dear IFEFFIT subscribers:
Please find here the info about the job opening:
Postdoctoral position at Yeshiva University
Physics Department of Yeshiva University in New York City has immediate opening
for a postdoctoral research associate position. The postdoc will investigate
thermal,