Dear Valerie
Sorry! I don't know where I got the idea that it was Fe, I was probably working
on Fe data at the time of writing. Having looked back I can see Mo.
"I am using Larch XAS Viewer for the first time to analyze some Mo XANES data.
It is fairly straightforward, however I am running
Dear Valerie
Which Fe standards are you looking to compare?
I have a large collection of Fe references collected from the SuperXAS beamline
all relatively recently and are all calibrated using Fe reference foil measured
simultaneously.
Using a Si(111) monochromator:
Fe2O3
Fe3C
Fe5C2
Fe3O4
your Subject line so it is more specific than "Re:
Contents of Ifeffit digest..."
Today's Topics:
1. Data Import Bug (Athena 0.9.26) (Clark Adam Hugh (PSI))
2. Re: Data Import Bug (Athena 0.9.26) (Ravel, Bruce)
3. Re: Data Import Bug (Athena 0.9.26) (Lucy
Dear Mailing List
I have recently come across a data import error when using Athena version
0.9.26. When importing data there appears to be a resampling which
significantly reduces the resolution of the data. Attached is an example
dataset with an energy step of 0.5 eV on the Cu K edge. When
Hi Matt
I recently had some problems incorporating the larch Cauchy wavelet transform
into my program for rapid bulk processing of QEXAFS data (discussed
http://millenia.cars.aps.anl.gov/pipermail/ifeffit/2014-April/007250.html). I
particular after importing the relevant module into python the