Dear all,
I have done Ti doped ZnO EXAFS data analysis but I guess it is getting mixture
structure at high concentration for example 55% Ti doped ZnO.Also I done linear
combination fit , but at fitting space norm(E),ZnO weight is 0.779 and ZnTiO3
is 0.221 then I changed fitting space is chi(k
Hi Andy,
Just a few notes I'd like to add to Carlo's helpful answer:
On Apr 6, 2009, at 1:27 PM, Carlo Segre wrote:
>
> Hi Andy:
>
> On Mon, 6 Apr 2009, Andy Connelly wrote:
>
>>
>> 2. If I want to refine the degeneracy of a path can I write the
>> expression "amp*N_1" in the SO2 box? (where the
Hi Luanga:
YOu will need to get FEFF8
Details are available at
http://leonardo.phys.washington.edu/feff/
Carlo
On Mon, 6 Apr 2009, Luanga Nchari wrote:
> I would like to do ab initio calculations to get a theoretical XANES spectra.
> I have XYZ coordinates.
> Could somebody remind me ho
Hi Andy,
I have a book chapter that details how to set the k-range for a data
set. It also talks about Rbkg in detail. If you want a copy just send
me an email.
Cheers,
Shelly
> -Original Message-
> From: ifeffit-boun...@millenia.cars.aps.anl.gov [mailto:ifeffit-
> boun...@millenia.ca
Hi Andy:
On Mon, 6 Apr 2009, Andy Connelly wrote:
>
> 1. Are there any problems if I set the R-range min to the same value as Rbkg?
No, but you shouldn't set it lower than Rbkg, in general.
>
> 2. If I want to refine the degeneracy of a path can I write the
> expression "amp*N_1" in the SO2 bo
Some really quick basic questions. I am working with EXAFS spectra of
silicate glasses at various edges (including S and Fe K edges) and I
am having a really difficult time pinning down the structures. Clearly
with glasses I can't always be sure of the oxygen co-ordination and so
I have to refine t
I would like to do ab initio calculations to get a theoretical XANES spectra. I
have XYZ coordinates.
Could somebody remind me how I can run this on my PC.
Cheers,
Luanga
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://mi
If the amplitudes in chi(k) are different, I would suggest that in the set with
the larger amplitude the logarithm of the ratio was not taken when importing
the data.
Jeremy
-Original Message-
From: ifeffit-boun...@millenia.cars.aps.anl.gov on behalf of Frenkel, Anatoly
Sent: Sun 4/5/2