Jose,
I am unclear what you are sad about. The version of Feff has little to
do with the quality of the analysis. See our recent paper:
https://doi.org/10.1107/S1600577517011651
It is true that feff8l would simplify and streamline the code, making it
easier to write and maintain. That's a bit incentive /for/ /me/ to do
that work.
But I think you are overstating the impact on the analysis you and
others do with Artemis.
B
On 01/12/2018 07:15 AM, José Carlos Conesa wrote:
OK Bruce, I understand. (Sigh)
Good luck in your actual job.
JC
El 12/01/2018 a las 12:35, Bruce Ravel escribió:
Yes. But I am pretty busy these with my new beamline.
"Beamline scientist" is my actual job. "Software guy" is a side
project. So the software work gets done when it gets done.
B
On 01/12/2018 05:25 AM, José Carlos Conesa wrote:
Dear Bruce,
Do you foresee that (in a not far future) Artemis may be adapted so
that it can use the results of feff8.5L?
All the best,
El 12/09/2017 a las 19:11, Bruce Ravel escribió:
Feff8L is not properly integrated into Artemis yet. Sorry. I have
a new beamline these days. It's hard to find time to work on the
software.
This is on my to do list, but it's going to take a while.
B
On 09/12/2017 12:54 PM, José Carlos Conesa wrote:
Hi,
I should like to use feff85L within Artemis (from Demeter 0.9.25),
just to check in my system whether selfconsistency has a role in
unifying E0 values (with feff 6, allowing different E0 for each
scatterer leads to E0 differences >10 eV, which seems too much to
me). I find that after loading the EXAFS data (from Athena) and a
model (a .cif file containing Cu, Ce and O atoms), if I click Run
Atoms and then Run Feff with feff6 as executable I get the usual
set of paths that allow me doing a fit of the data, but if I try to
use the feff85L.exe that comes with the Demeter software (by
changing the feff executable in the File/Edit preferences menu),
after clicking the Run Feff button (without including the SCF card)
a bit of computation happens and after finishing it the path list
is empty.
¿Any idea of the possible reason why I get no path list?
Thanks in advance
--
Bruce Ravel bra...@bnl.gov
National Institute of Standards and Technology
Synchrotron Science Group at NSLS-II
Building 743, Room 114
Upton NY, 11973
Homepage:http://bruceravel.github.io/home/
Beamline:https://www.bnl.gov/ps/beamlines/beamline.php?r=6-BM
Software:https://github.com/bruceravel
Demeter: http://bruceravel.github.io/demeter/
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit