[Ifeffit] Amplitude ratios greater than 100%

2019-04-01 Thread Raj kumar
Dear All, With the attached CIF file, i have generated chi and other files. In turn, for some paths, i have found amplitude ratios are greater than 100% (even it is reaching few thousands % for some paths - chi file also attached with this email). I know, it is meaningless. I would like to know, w

Re: [Ifeffit] Ifeffit Digest, Vol 189, Issue 8

2018-11-02 Thread Raj kumar
-- next part -- > An HTML attachment was scrubbed... > URL: < > http://millenia.cars.aps.anl.gov/pipermail/ifeffit/attachments/20181102/b637c308/attachment-0001.html > > > > -- > > Message: 2 > Date: Fri, 2 Nov

Re: [Ifeffit] Ifeffit Digest, Vol 189, Issue 2

2018-11-01 Thread Raj kumar
AFS > Message-ID: > < > cafsmozbm2rmvuermuoryw9ehvrzqcvx60zhqufmk39olroy...@mail.gmail.com> > Content-Type: text/plain; charset="utf-8" > > It is an effect of inhomogeneity of the sample, that is, the variation in > the metal density throughout the X-ray beam foo

[Ifeffit] Bump/oscillating pattern at high energies of EXAFS

2018-11-01 Thread Raj kumar
Dear All, I have monitored the growth process of YbVO4 nanoparticles using EXAFS. Here, nanoparticles were synthesized in water medium. Both initial and final products (EXAFS) of the synthesis were measured using the continuous flow approach whereas the intermediate products were recorded, in the

[Ifeffit] In-situ bulk data analysis

2017-01-10 Thread Raj kumar
Dear All, I am looking for an EXAFS software to handle bulk data and perform both linear combination and regular EXAFS fit. Regards, Raj ___ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit

Re: [Ifeffit] Ifeffit Digest, Vol 167, Issue 14

2017-01-09 Thread Raj kumar
k > > *I say ?never,? but I can think of one case where it might be justified, > and wouldn?t be surprised if there are others. If you were trying to decide > between a compound being 4-coordinated or 6-coordinated, and had some > reason for thinking it was purely one or the o

[Ifeffit] Problem with large so2: Updated

2017-01-05 Thread Raj kumar
Dear all, Earlier, I have posted few questions on large so2 value and got valuable suggestions from Scott and Bruce. Here i am presenting my summary of earlier emails and the present views. Could you please tell me whether am i going in right direction. I have been trying to fit EXAFS signal of

Re: [Ifeffit] Ifeffit Digest, Vol 167, Issue 3

2017-01-05 Thread Raj kumar
Today's Topics: > >1. Re: Ifeffit Digest, Vol 167, Issue 2 (Raj kumar) >2. Re: Ifeffit Digest, Vol 167, Issue 2 (Bruce Ravel) >3. Re: Ifeffit Digest, Vol 167, Issue 2 (Raj kumar) > > > -----------

Re: [Ifeffit] Ifeffit Digest, Vol 167, Issue 3

2017-01-04 Thread Raj kumar
replying, please edit your Subject line so it is more specific > than "Re: Contents of Ifeffit digest..." > > > Today's Topics: > >1. Re: Ifeffit Digest, Vol 167, Issue 2 (Raj kumar) >2. Re: Ifeffit Digest, V

Re: [Ifeffit] Ifeffit Digest, Vol 167, Issue 2

2017-01-04 Thread Raj kumar
Hi Scott, I would like to add an extra point to the previous message. Yes, i am getting a large uncertainty for the second so2 (2.04 +/- 1.36). Regards, Raj On 3 January 2017 at 21:32, Raj kumar wrote: > Hi Scott, > > Thank you very much for your prompt response. EXAFS measurement

Re: [Ifeffit] Ifeffit Digest, Vol 167, Issue 2

2017-01-03 Thread Raj kumar
esent than what you modelled) or that the model includes split > distances when in reality the compound is more symmetric. > > In short, no, the high second S02 does not make sense (although it would > be good to know the uncertainties). > > Best, > Scott Calvin > Lehman College

Re: [Ifeffit] Ifeffit Digest, Vol 166, Issue 22

2016-12-23 Thread Raj kumar
Hi Guanghui, Final particle size of these nanoparticles are about 30-40 nm. Regards, Raj On 23 December 2016 at 19:00, wrote: > Send Ifeffit mailing list submissions to > ifeffit@millenia.cars.aps.anl.gov > > To subscribe or unsubscribe via the World Wide Web, visit > http://mi

Re: [Ifeffit] Ifeffit Digest, Vol 166, Issue 12

2016-12-16 Thread Raj kumar
;s Topics: > >1. Web Atoms 1.8 vs Demeter 0.9.26: feff output are not same > (Raj kumar) >2. Re: Web Atoms 1.8 vs Demeter 0.9.26: feff output are not same > (Bruce Ravel) > > > ------ > > M

[Ifeffit] Web Atoms 1.8 vs Demeter 0.9.26: feff output are not same

2016-12-16 Thread Raj kumar
Dear All, Recently, i found out that feff.inp generated by web atoms and Demeter 0.9.26 are not the same. My main worry is in the position of atoms. For evidence, i am attaching YbVO4 (*feff.inp*) files generated by both web atoms and Demeter. With this kind of zircon type structure, one would exc

Re: [Ifeffit] Ifeffit Digest, Vol 147, Issue 20

2015-05-29 Thread Raj kumar
- > > Message: 1 > Date: Fri, 29 May 2015 12:52:38 -0400 > From: Bruce Ravel > To: XAFS Analysis using Ifeffit > Subject: Re: [Ifeffit] Peak at short distance in FT - YbVO4 > nanoparticles > Message-ID: <55689956.8040...@bnl.gov> > Content-Type: text/plain

[Ifeffit] Peak at short distance in FT - YbVO4 nanoparticles

2015-05-29 Thread Raj kumar
Dear All, Recently, i have performed EXAFS for YbVO4 bulk (prepared through sintering process) and nanoparticles (at room temperature). Nanoparticles were synthesized by co-precipitation technique and their EXAFS was measured by passing the prepared solution using peristaltic pump. After all subtr

Re: [Ifeffit] (D)Artemis shutting down automatically

2015-03-11 Thread Raj kumar
;2. Re: Data being overwritten in Artemis history window (Bruce Ravel) >3. (D)Artemis shutting down automatically (Raj kumar) >4. Re: (D)Artemis shutting down automatically (Bruce Ravel) > > > -- >

[Ifeffit] (D)Artemis shutting down automatically

2015-03-11 Thread Raj kumar
Dear All, Recently, i have faced automatic shutting down of artemis during the import of chi file. For more clarification, please see the first log file. Also, i observed emptying of .fpj files. This happens during the saving of old .apj to .fpj or/and during the frequent saving of .fpj files aft