Hello, Mike et al.,
you can correct for self-absorption using the "self-absorption correction
tool" in Athena, as long as the chemical composition of your sample is
known.
In case it's not possible to determine the chemical composition of you
sample, and your sample is conductive, then running
are of limited quality and there will be severe
limits on how much information you will be able to extract from them.
B
-- Forwarded Message --
Subject: P-EXAFS fitting results and multiple scattering
Date: Sunday, April 22, 2012, 05:08:14 pm
From: daltonabd...@gmail.com
Lawrence College
P.S. Make sure you send email related to this chapter to my address
directly, and not to the Ifeffit list.
On Dec 14, 2011, at 2:39 PM, daltonabd...@gmail.commailto:
daltonabd...@gmail.com wrote:
Hi Scott,
I'd be willing to review this chapter. Just to touch base, we met
Hi Scott,
I'd be willing to review this chapter. Just to touch base, we met each
other at SSRL last May. I'm a PhD student at Dr. Sparks research group
doing research on P-EXAFS.
Thank you,
Dalton
On Wed, Dec 14, 2011 at 11:09 AM, Scott Calvin scal...@sarahlawrence.eduwrote:
Hi all,
I