From: Piotr Maciejewski
i915 used to support time based
On 16/07/2020 21:06, Umesh Nerlige Ramappa wrote:
On Thu, Jul 16, 2020 at 06:32:10PM +0300, Lionel Landwerlin wrote:
On 14/07/2020 10:22, Umesh Nerlige Ramappa wrote:
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not
On Thu, Jul 16, 2020 at 06:32:10PM +0300, Lionel Landwerlin wrote:
On 14/07/2020 10:22, Umesh Nerlige Ramappa wrote:
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not enough for query mode used to measure a
single
On 14/07/2020 10:22, Umesh Nerlige Ramappa wrote:
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not enough for query mode used to measure a
single draw call or dispatch. Gen9-Gen11 are using current i915 perf
Quoting Umesh Nerlige Ramappa (2020-07-14 21:10:02)
> On Tue, Jul 14, 2020 at 12:28:15PM +0100, Chris Wilson wrote:
> >Quoting Umesh Nerlige Ramappa (2020-07-14 08:22:39)
> >> From: Piotr Maciejewski
> >>
> >> i915 used to support time based sampling mode which is good for overall
> >> system
On Tue, Jul 14, 2020 at 12:28:15PM +0100, Chris Wilson wrote:
Quoting Umesh Nerlige Ramappa (2020-07-14 08:22:39)
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not enough for query mode used to measure a
single draw
Quoting Umesh Nerlige Ramappa (2020-07-14 08:22:39)
> From: Piotr Maciejewski
>
> i915 used to support time based sampling mode which is good for overall
> system monitoring, but is not enough for query mode used to measure a
> single draw call or dispatch. Gen9-Gen11 are using current i915 perf
On Tue, Jul 14, 2020 at 12:22:39AM -0700, Umesh Nerlige Ramappa wrote:
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not enough for query mode used to measure a
single draw call or dispatch. Gen9-Gen11 are using
From: Piotr Maciejewski
i915 used to support time based sampling mode which is good for overall
system monitoring, but is not enough for query mode used to measure a
single draw call or dispatch. Gen9-Gen11 are using current i915 perf
implementation for query, but Gen12+ requires a new approach