Em Seg, 2018-08-06 às 12:58 +0300, Imre Deak escreveu:
> There is no need for separate IDs for power wells on a new platform
> with
> the same functionality as an other power well on a previous platform,
> we
> can just reuse the ID from the previous platform. This is only
> possible
> after the
There is no need for separate IDs for power wells on a new platform with
the same functionality as an other power well on a previous platform, we
can just reuse the ID from the previous platform. This is only possible
after the previous patches where we removed dependence on the actual
enum