On Thu, Sep 17, 2020 at 07:32:27PM +0200, Christoph Hellwig wrote:
>  static int __init cats_pci_init(void)
>  {
> -     if (machine_is_cats())
> -             pci_common_init(&cats_pci);
> +     if (!machine_is_cats())
> +             return 0;
> +     bus_register_notifier(&pci_bus_type, &footbridge_pci_dma_nb);
> +     pci_common_init(&cats_pci);

I'd prefer these things to retain a positive-logic construct, so:

        if (machine_is_cats()) {
                bus_register_notifier(&pci_bus_type, &footbridge_pci_dma_nb);
                pci_common_init(&cats_pci);
        }

It's the same number of lines.

Otherwise, I think it's fine. I'll try to find some spare time to give
it a go on a Netwinder.

-- 
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!