Abhishek Singh Chouhan created HBASE-23825:
----------------------------------------------

             Summary: Increment proto conversion is broken
                 Key: HBASE-23825
                 URL: https://issues.apache.org/jira/browse/HBASE-23825
             Project: HBase
          Issue Type: Bug
    Affects Versions: 1.4.12, 1.3.6, 1.5.0
            Reporter: Abhishek Singh Chouhan
            Assignee: Abhishek Singh Chouhan


While converting the request back to Increment using ProtobufUtil.toIncrement 
we incorrectly use the optimization to avoid copying the byte 
array(HBaseZeroCopyByteString#zeroCopyGetBytes) on a BoundedByteString. The 
optimization was only meant for LiteralByteString where it is safe to use the 
backing byte array, however it ends up being used to BoundedByteString which is 
a subclass of LiteralByteString. This essentially breaks increments since we 
end up creating wrong cells on the server side. 



--