Oh, thanks Bob
I should have known, since contacts are a kind of isosurface! I knew ID is
essential to have several at a time, but I missed that bit now.
This is going to look great!
Thanks
---
El software de antivirus Avast ha analizado este correo electrónico en busca de
virus.
https://ww
Not a bug. You just have to be careful to use the ID and atom selection
carefully
load =1blu
contact ID c1 {SF4}
load append =1d66
contact ID c2 {nucleic and 2.1}
If you leave off ID, then the two have the same default id, "contact1", and
so the first is lost when the second appears.
If you leave
definitely a bug.
--
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot___
Jmol-users mailing list
Jmol-us
It seems that the result of "contact" cannot be present separately in the two
frames when 2 models have been loaded. Only the latest generated set of
contacts is displayed, and only in the current frame (even if calculated from
atoms in the other frame).
Is there a way around? We would like to
4 matches