https://bugs.kde.org/show_bug.cgi?id=420920

            Bug ID: 420920
           Summary: Tooltip and popup of battery applet show different
                    battery levels
           Product: plasmashell
           Version: master
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: Battery Monitor
          Assignee: k...@privat.broulik.de
          Reporter: bugsefor...@gmx.com
                CC: plasma-b...@kde.org
  Target Milestone: 1.0

Created attachment 128100
  --> https://bugs.kde.org/attachment.cgi?id=128100&action=edit
screen recording

STEPS TO REPRODUCE
1. disconnect the ac adapter from your laptop
2. use your device during a few minutes/hours or just wait for the battery
level to decrease
3. reconnect the ac adapter to your device and wait for your battery to be
charged
4. observe the battery level hovering over the battery applet in systray.
Also click on such applet and observe the percentage of "Charging".

OBSERVED RESULT
Tooltip and popup of battery applet show different battery levels.
Watch the attached screen recording please.

EXPECTED RESULT
Tooltip and popup of battery applet should show the same battery level

SOFTWARE/OS VERSIONS
Operating System: KDE neon Unstable Edition
KDE Plasma Version: 5.18.80
KDE Frameworks Version: 5.70.0