Public bug reported:

[Impact] 
There's a high chance that MT7921 BT may go out to lunch after reboot.
Worse, there's no way to recover the controller unless the power cord is
unplugged.

[Fix]
In addition to SRU "Need to reset MT7921 BT when the firmware hang or
command no response", enable MSFT extension can magically solve the
issue. 

[Test]
With the patch applied, the MT7921 BT continues to work after 100 times
reboots.

[Where problems could occur]
This fix is specific to MTK BT controllers, so the change is limited.

I totally don't understand why this patch can fix the issue, other than
it just does the trick. So I guess we have to accept the reality that
hardwares can have their own quirks.

** Affects: hwe-next
     Importance: Undecided
         Status: New

** Affects: linux-oem-5.14 (Ubuntu)
     Importance: Undecided
         Status: Invalid

** Affects: linux-oem-5.14 (Ubuntu Focal)
     Importance: Medium
         Status: Confirmed


** Tags: oem-priority originate-from-1961591 sutton

** Also affects: linux-oem-5.14 (Ubuntu Focal)
   Importance: Undecided
       Status: New

** Changed in: linux-oem-5.14 (Ubuntu Focal)
       Status: New => Confirmed

** Changed in: linux-oem-5.14 (Ubuntu Focal)
   Importance: Undecided => Medium

** Changed in: linux-oem-5.14 (Ubuntu)
       Status: New => Invalid

** Tags added: oem-priority originate-from-1961591 sutton

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux-oem-5.14 in Ubuntu.
https://bugs.launchpad.net/bugs/1966497

Title:
   Fix non-working MT7921 BT after reboot

Status in HWE Next:
  New
Status in linux-oem-5.14 package in Ubuntu:
  Invalid
Status in linux-oem-5.14 source package in Focal:
  Confirmed

Bug description:
  [Impact] 
  There's a high chance that MT7921 BT may go out to lunch after reboot.
  Worse, there's no way to recover the controller unless the power cord is
  unplugged.

  [Fix]
  In addition to SRU "Need to reset MT7921 BT when the firmware hang or
  command no response", enable MSFT extension can magically solve the
  issue. 

  [Test]
  With the patch applied, the MT7921 BT continues to work after 100 times
  reboots.

  [Where problems could occur]
  This fix is specific to MTK BT controllers, so the change is limited.

  I totally don't understand why this patch can fix the issue, other than
  it just does the trick. So I guess we have to accept the reality that
  hardwares can have their own quirks.

To manage notifications about this bug go to:
https://bugs.launchpad.net/hwe-next/+bug/1966497/+subscriptions


-- 