[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-18 Thread Adam Lyall
My dmidecode bio info:
GCETA0WW (2.60 )
09/12/2014

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-18 Thread Christopher M. Penalver
Adam Lyall, could you please provide the missing information following
https://wiki.ubuntu.com/DebuggingKernelSuspend ?

** Tags added: latest-bios-2.60

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-18 Thread Adam Lyall
Here are the debug bits that guide asks for.

** Attachment added: wakeup
   
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+attachment/4321770/+files/wakeup

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-18 Thread Adam Lyall
This is the dmesg log after resuming from:
sudo sh -c sync  echo 1  /sys/power/pm_trace  pm-suspend
Note that as the usb peripherals were non-responsive as expected, after resume 
I had to disconnect from the dock and reconnect the laptop to it.

** Attachment added: dmesg-after-trace-resume.txt
   
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+attachment/4321772/+files/dmesg-after-trace-resume.txt

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-18 Thread Christopher M. Penalver
Adam Lyall, the issue you are reporting is an upstream one. Could you
please report this problem to the appropriate mailing list (linux-acpi)
by following the instructions verbatim at
https://wiki.ubuntu.com/Bugs/Upstream/kernel ?

Please provide a direct URL to your e-mail to the mailing list once you
have made it so that it may be tracked via http://vger.kernel.org/vger-
lists.html . It can take a day for the new e-mail to show up in the
respective archive.

Thank you for your understanding.

** Changed in: linux (Ubuntu)
   Status: Confirmed = Triaged

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Triaged

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-17 Thread Christopher M. Penalver
Adam Lyall, could you please provide the output of the following terminal 
command:
sudo dmidecode -s bios-version  sudo dmidecode -s bios-release-date

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-17 Thread Adam Lyall
The problem is still present with the latest Lenovo bios (2.60) and
Linux 3.19.

** Tags removed: bios-outdated-2.60 kernel-bug-exists-upstream-3.18-rc4 
needs-upstream-testing
** Tags added: kernel-bug-exists-upstream-3.19

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-02-16 Thread Adam Lyall
Finally been able to test Linux 3.5.7 from the kernel ppa () and the
same issue was there. I didn't realise there was a new bios out so I'll
test that soon and I'll test Linux 3.19.

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-01-09 Thread Adam Lyall
Sorry I've not been able to get back onto this yet. I currently don't
have access to the dock but will in a couple of weeks and I'll do some
more testing.

** Tags added: kernel-bug-exists-upstream-3.18-rc4

** Changed in: linux (Ubuntu)
   Status: Expired = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-01-09 Thread Christopher M. Penalver
** Tags removed: kernel-bug-exists-upstream kernel-bug-exists-upstream-3.18-rc3
** Tags added: needs-upstream-testing

** Tags added: bios-outdated-2.60

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2015-01-08 Thread Launchpad Bug Tracker
[Expired for linux (Ubuntu) because there has been no activity for 60
days.]

** Changed in: linux (Ubuntu)
   Status: Incomplete = Expired

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in linux package in Ubuntu:
  Expired

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-09 Thread Adam Lyall
I don't think that is going to be practical. If I get some spare time I
will try a live 12.04 environment but this bug normally takes days to
occur and I will just not be able to run the live environment for that
long. I may be able to test the kernel from 14.04 if you have
suggestions on how to do that or should I just grab the same version
from the kernel PPA? However I am concerned with hardware support as I
recall Intel Ivybridge based chips not being so great on 12.04. I
started using Ubuntu with this laptop from 12.10.

Thanks.

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-09 Thread Christopher M. Penalver
Adam Lyall, you could install just the kernel from Quantal following
https://wiki.ubuntu.com/Kernel/KernelBisection#Bisecting_Ubuntu_kernel_versions
.

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Adam Lyall
I've been running Linux kernel 3.18-rc3 for 6 days and just run into the issue. 
I think now that the length of time a system has been running without a reboot 
can cause the issue as I only suspended for an hour and upon resume the usb 
devices on the dock were no longer working until I un-docked and re-docked. The 
usual dmesg errors were present:
[265522.355189] usb 1-3.4: USB disconnect, device number 8
[265524.344756] usb 1-3.4: new low-speed USB device number 9 using xhci_hcd
[265524.468746] usb 1-3.4: New USB device found, idVendor=045e, idProduct=00dd
[265524.468752] usb 1-3.4: New USB device strings: Mfr=1, Product=2, 
SerialNumber=0
[265524.468755] usb 1-3.4: Product: Comfort Curve Keyboard 2000
[265524.468757] usb 1-3.4: Manufacturer: Microsoft
[265524.468983] usb 1-3.4: ep 0x81 - rounding interval to 64 microframes, ep 
desc says 80 microframes
[265524.468989] usb 1-3.4: ep 0x82 - rounding interval to 64 microframes, ep 
desc says 80 microframes
[265524.468999] xhci_hcd :00:14.0: Not enough bandwidth on HS bus for newly 
activated TT.
[265524.469004] xhci_hcd :00:14.0: Not enough bandwidth
[265524.469011] usb 1-3.4: can't set config #1, error -12
[265539.568853] ACPI: \_SB_.GDCK: undocking
[265539.572735] ata2: exception Emask 0x10 SAct 0x0 SErr 0x409 action 0xe 
frozen
[265539.572742] ata2: irq_stat 0x00400040, connection status changed
[265539.572749] ata2: SError: { PHYRdyChg 10B8B DevExch }
[265539.572758] ata2: hard resetting link
[265540.296949] ata2: SATA link down (SStatus 0 SControl 300)
[265545.298281] ata2: hard resetting link
[265545.618332] ata2: SATA link down (SStatus 0 SControl 300)
[265545.618341] ata2: limiting SATA link speed to 1.5 Gbps
[265546.197581] usb 1-3: USB disconnect, device number 2
[265546.197587] usb 1-3.3: USB disconnect, device number 7
[265546.197906] usb 1-3.4: USB disconnect, device number 9
[265546.823120] thinkpad_acpi: EC reports that Thermal Table has changed
[265546.926796] thinkpad_acpi: undocked from hotplug port replicator
[265546.926878] ACPI: \_SB_.GDCK: undocking


** Tags added: kernel-bug-exists-upstream-3.18-rc3

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 

[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Christopher M. Penalver
Adam Lyall, did this problem not occur in a release prior to Utopic?

** Tags removed: kernel-bug-exists-upstream-3.17.1

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Adam Lyall
Yes it is present in Ubuntu 14.04. If you see bug #1116525 then it seems
this issue was present and affecting other users from at least Ubuntu
12.10.

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Christopher M. Penalver
Adam Lyall, just to clarify, what is requested is when you tested in
personally (not someone else on some other report) was this not
reproducible prior to Trusty?

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

** Tags added: trusty

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Adam Lyall
I'm afraid I did not have the dock prior to Trusty so I have no
experience with any earlier versions of Ubuntu.

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-08 Thread Christopher M. Penalver
Adam Lyall, for regression testing purposes, could you please test a
live environment of 12.04.0 with kernel 3.2.x (not 12.04.5 or some other
variant) via http://old-releases.ubuntu.com/releases/12.04.0/ and advise
to the results?

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-02 Thread Adam Lyall
** Tags added: kernel-bug-exists-upstream kernel-bug-exists-
upstream-3.17.1

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-02 Thread Adam Lyall
OK so things seems worse on 3.17.1. After resuming my laptop from about
10-11 hours sleep, not only were the inputs connected to the USB docks
not working, but after initial display my screen did not seem to be
updating (no flashing cursor on log in screen), and the keys and
trackpad on the laptop itself did not work. I disconnected the dock and
reconnected but still nothing. However, the screen on my external
monitor went off as expected but came back after reconnecting. I had
thought maybe a hard hang had happened but with the screen coming back
that seemed unlikely. I hit CTRL+ALT+F1 to switch to a terminal and
nothing happened. I then disconnected again and my laptop screen jumped
over to the terminal as if it had registered the CTRL+ALT+F1 previously.
Connecting again showed the terminal on my external screen but still the
USB keyboard connected to the dock did not work but disconnecting again
I found the laptop keys were working. I logged into the terminal and ran
dmesg. I then connected to the dock again and my USB keyboard and mouse
started working! :-/

After logging back into the desktop I found I had no wifi. I had seen this 
previously while testing a version of 3.17 in the past. After flicking my wifi 
hard switch off/on it still did not work and dmesg showed this odd bit (I know 
this is another issue but adding for prosperity):
 [44576.665593] iwlwifi :03:00.0: RF_KILL bit toggled to disable radio.
[44576.920342] usb 1-1.4: USB disconnect, device number 3
[44584.021782] iwlwifi :03:00.0: RF_KILL bit toggled to enable radio.
[44584.352335] usb 1-1.4: new full-speed USB device number 5 using ehci-pci
[44584.448489] usb 1-1.4: New USB device found, idVendor=0a5c, idProduct=21e6
[44584.448494] usb 1-1.4: New USB device strings: Mfr=1, Product=2, 
SerialNumber=3
[44584.448497] usb 1-1.4: Product: BCM20702A0
[44584.448500] usb 1-1.4: Manufacturer: Broadcom Corp
[44584.448502] usb 1-1.4: SerialNumber: E006E6B74E8D
[44584.451317] bluetooth hci0: Direct firmware load for 
brcm/BCM20702A0-0a5c-21e6.hcd failed with error -2
[44584.451323] bluetooth hci0: Falling back to user helper
[44584.452125] Bluetooth: hci0: BCM: patch brcm/BCM20702A0-0a5c-21e6.hcd not 
found

The wifi or ethernet still did not work and ifconfig showed the interfaces were 
missing so I ran:
$ sudo service networking restart
$ sudo service network-manager restart

and wifi came back alive (along with the bluetooth which I had not
actually checked).

So lots of fun with 3.17 :(

As for testing 3.18rc1, I am hesitant as I really don't like testing an
RC1 release on my production laptop. I might still but I'll likely wait
for an RC3 release to try next.

I'm attaching what my dmesg looked like after resume. If you are
interested I can attach another which was run after I got the networking
working again?

** Attachment added: dmesg after resume
   
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+attachment/4251138/+files/dock-hang-on-resume-dmesg-linux.3.17.txt

** Changed in: linux (Ubuntu)
   Status: Incomplete = Confirmed

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release 

[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-02 Thread Christopher M. Penalver
Adam Lyall, this is pending a 3.18-rc1+ test. Once complete, then please
mark this Status Confirmed.

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-01 Thread Adam Lyall
Just tried Linux Kernel 3.18.0-031800rc2_3.18.0-031800rc2.201410262035
from the PPA which simply fails to properly boot and falls to a busybox
console because for some reason it fails to find the root drive.
Considering its an rc2 release it was not unexpected to run into some
unrelated issues. FYI the failed boot output was:

Gave up waiting for root device. Common problems:
- Boot args (cat /proc/cmdline)
  - Check rootdelay= (did the system waut long enough?)
  - Check root= (did the system wait for the right device?)
- Missing modules (cat /proc/modules; ls /dev)
ALERT! /dev/disk/by-uuid/MYROOT-DRIVE-UUID does not exist. Dropping to a shell!

BusyBox v1.22.1 (Ubuntu 1:1.22.0-8ubuntu1) built-in shell (ash)

I'm now running 3.17.1-031701_3.17.1-031701.201410150735_all instead. If
I don't get the issue I will report back end of next week as it takes a
while for it to get triggered.

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-11-01 Thread Christopher M. Penalver
Adam Lyall, if reproducible in 3.17.1, could you please test 3.18-rc1
instead?

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Incomplete

Bug description:
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours, upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive).

  Shorter periods of standby seem unaffected unless the issues has
  already occurred. E.g. After a fresh boot if I suspend my laptop and
  resume after less than about 8 hours (I am not at all certain if the
  period of time is related. Just general observation), everything will
  continue to work fine. If however the issue has occurred at some point
  and I have disconnected and reconnected to work around the issue, and
  then I suspend for a short period of time (20 seconds) and resume, the
  dock's USB ports will no longer work unless I again disconnect the
  laptop from the dock and reconnect. So it seems once the issue has
  happened it will continue to happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1388072/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp


[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-10-31 Thread Adam Lyall
** Description changed:

  Please see:
  https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1116525
  
  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3 dock
  and suspended for many hours. Upon resume the USB ports on the dock, but
  not the laptop, stop working with peripherals (mouse, keyboard, usb
- drive). Shorter periods of standby seem unaffected.
+ drive). Shorter periods of standby seem unaffected unless the issues has
+ already occurred. E.g. After a fresh boot if I suspend my laptop and
+ resume after less than about 8 hours (I am not at all certain if the
+ period of time is related. Just general observation), everything will
+ continue to work fine. If however the issue has occurred at some point
+ and I have disconnected and reconnected to work around the issue, and
+ then I suspend for a short period of time (20 seconds) and resume, the
+ dock's USB ports will no longer work unless I again disconnect the
+ laptop from the dock and reconnect. So it seems once the issue has
+ happened it will continue to happen until I reboot.
  
  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
-  USERPID ACCESS COMMAND
-  /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
+  USERPID ACCESS COMMAND
+  /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
-  linux-restricted-modules-3.16.0-23-generic N/A
-  linux-backports-modules-3.16.0-23-generic  N/A
-  linux-firmware 1.138
+  linux-restricted-modules-3.16.0-23-generic N/A
+  linux-backports-modules-3.16.0-23-generic  N/A
+  linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1388072

Title:
  [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer
  working after resuming from long standby

Status in “linux” package in Ubuntu:
  Confirmed

Bug description:
  Please see:
  https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1116525

  When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3
  dock and suspended for many hours. Upon resume the USB ports on the
  dock, but not the laptop, stop working with peripherals (mouse,
  keyboard, usb drive). Shorter periods of standby seem unaffected
  unless the issues has already occurred. E.g. After a fresh boot if I
  suspend my laptop and resume after less than about 8 hours (I am not
  at all certain if the period of time is related. Just general
  observation), everything will continue to work fine. If however the
  issue has occurred at some point and I have disconnected and
  reconnected to work around the issue, and then I suspend for a short
  period of time (20 seconds) and resume, the dock's USB ports will no
  longer work unless I again disconnect the laptop from the dock and
  reconnect. So it seems once the issue has happened it will continue to
  happen until I reboot.

  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days 

[Kernel-packages] [Bug 1388072] Re: [Lenovo ThinkPad X230 Tablet] USB devices in docking station no longer working after resuming from long standby

2014-10-31 Thread Christopher M. Penalver
Adam Lyall, thank you for reporting this and helping make Ubuntu better. Could 
you please test the latest upstream kernel available from the very top line at 
the top of the page (not the daily folder) following 
https://wiki.ubuntu.com/KernelMainlineBuilds ? It will allow additional 
upstream developers to examine the issue. Once you've tested the upstream 
kernel, please comment on which kernel version specifically you tested. If this 
bug is fixed in the mainline kernel, please add the following tags:
kernel-fixed-upstream
kernel-fixed-upstream-VERSION-NUMBER

where VERSION-NUMBER is the version number of the kernel you tested exactly 
shown as:
kernel-fixed-upstream-3.18-rc1

This can be done by clicking on the yellow circle with a black pencil
icon next to the word Tags located at the bottom of the bug description.

If the mainline kernel does not fix this bug, please add the following tags:
kernel-bug-exists-upstream
kernel-bug-exists-upstream-VERSION-NUMBER

Once testing of the upstream kernel is complete, please mark this bug's
Status as Confirmed. Please let us know your results. Thank you for your
understanding.

** Description changed:

- Please see:
- https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1116525
+ When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3 dock
+ and suspended for many hours, upon resume the USB ports on the dock, but
+ not the laptop, stop working with peripherals (mouse, keyboard, usb
+ drive).
  
- When my Lenovo Thinkpad x230t is attached to an Ultrabase Series 3 dock
- and suspended for many hours. Upon resume the USB ports on the dock, but
- not the laptop, stop working with peripherals (mouse, keyboard, usb
- drive). Shorter periods of standby seem unaffected unless the issues has
- already occurred. E.g. After a fresh boot if I suspend my laptop and
- resume after less than about 8 hours (I am not at all certain if the
- period of time is related. Just general observation), everything will
- continue to work fine. If however the issue has occurred at some point
- and I have disconnected and reconnected to work around the issue, and
- then I suspend for a short period of time (20 seconds) and resume, the
- dock's USB ports will no longer work unless I again disconnect the
- laptop from the dock and reconnect. So it seems once the issue has
- happened it will continue to happen until I reboot.
+ Shorter periods of standby seem unaffected unless the issues has already
+ occurred. E.g. After a fresh boot if I suspend my laptop and resume
+ after less than about 8 hours (I am not at all certain if the period of
+ time is related. Just general observation), everything will continue to
+ work fine. If however the issue has occurred at some point and I have
+ disconnected and reconnected to work around the issue, and then I
+ suspend for a short period of time (20 seconds) and resume, the dock's
+ USB ports will no longer work unless I again disconnect the laptop from
+ the dock and reconnect. So it seems once the issue has happened it will
+ continue to happen until I reboot.
  
  ProblemType: Bug
  DistroRelease: Ubuntu 14.10
  Package: linux-image-3.16.0-23-generic 3.16.0-23.31
  ProcVersionSignature: Ubuntu 3.16.0-23.31-generic 3.16.4
  Uname: Linux 3.16.0-23-generic x86_64
  ApportVersion: 2.14.7-0ubuntu8
  Architecture: amd64
  AudioDevicesInUse:
   USERPID ACCESS COMMAND
   /dev/snd/controlC0:  magicmyth   4476 F pulseaudio
  CurrentDesktop: KDE
  Date: Fri Oct 31 12:45:03 2014
  EcryptfsInUse: Yes
  HibernationDevice: RESUME=UUID=9204d11f-56e2-4eff-9bae-80cd829eef89
  InstallationDate: Installed on 2012-08-15 (807 days ago)
  InstallationMedia: Ubuntu 12.04 LTS Precise Pangolin - Release amd64 
(20120425)
  MachineType: LENOVO 3435CTO
  ProcFB: 0 inteldrmfb
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-3.16.0-23-generic 
root=UUID=8c85-b9c7-41ec-8e1c-24eb1d5e089b ro quiet splash zswap.enabled=1 
vt.handoff=7
  RelatedPackageVersions:
   linux-restricted-modules-3.16.0-23-generic N/A
   linux-backports-modules-3.16.0-23-generic  N/A
   linux-firmware 1.138
  SourcePackage: linux
  UpgradeStatus: Upgraded to utopic on 2014-10-25 (5 days ago)
  dmi.bios.date: 05/28/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GCET99WW (2.59 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 3435CTO
  dmi.board.vendor: LENOVO
  dmi.board.version: Not Defined
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGCET99WW(2.59):bd05/28/2014:svnLENOVO:pn3435CTO:pvrThinkPadX230Tablet:rvnLENOVO:rn3435CTO:rvrNotDefined:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.name: 3435CTO
  dmi.product.version: ThinkPad X230 Tablet
  dmi.sys.vendor: LENOVO

** Changed in: linux (Ubuntu)
   Importance: Undecided = Medium

** Changed in: linux (Ubuntu)
   Status: Confirmed = Incomplete

-- 
You received this bug