On Wed, 13 Jan 2010 20:42:09 -0800
That usually means one of two things.
1. The device is expecting something to be connected to that pin, and
there is nothing there. i.e. it.s an I/O pin which you are not using. If
that is the case put a no connection X on it.
2. You have a mismatch in grid
The output from ERC will tell you what the error is and where. So that
should give a few clues as to what is going on.
I must admit that I don't like your comment that things change when you
have not moved anything.
The two main problems in eescgema is making sure that you have junctions
at the
It is always the same error :(
ErrType(2): Pin not connected (and no connect symbol found on this pin)
@
(3.0500 ,4.2500 ): Cmp P1, Pin 28 (passive) Unconnected
I have been having trouble in eeschema, even though i have connected all the
pins on a connector, some of them fail ERC, and occasionally some that pass ERC
fail ERC later, even though I have not moved anything.
I am primarily working on a mac pro under mac OSX, but i am getting the same