daystar1013 a écrit :
>
> The new format for eeschema appears to be causing problems with local
> labels, global labels, and the new hierarchical label when generating
> netlists.
> I am working with a schematic that several people have been working on.
> It has a root sheet, a sheet inside the root and another one in the
> second level sheet.
> When the netlist was generated nets were merged for no apparent reason
> and given names that were not specified on any net. The PCB
> interconnectivity was really screwed up.
>
"New" hierarchical labels are the old global labels. the current global 
labels are new and are actually "globals" (as said in new doc)
I have no problem with new eeschema labels handling.
So, can you send me your kicad project ?


-- 

Jean-Pierre CHARRAS

Maître de conférences
Directeur d'études 2ieme année.
Génie Electrique et Informatique Industrielle 2
Institut Universitaire de Technologie 1 de Grenoble
BP 67, 38402 St Martin d'Heres Cedex

Recherche :
GIPSA-LIS - INPG
46,  Avenue Félix Viallet
38031 Grenoble cedex


Reply via email to