Hi all,
I am new to the world of Linrad, so my request can be obvious for many...sorry. I am using a notebook with Audigy2 ZS PCMCIA audio card running at 96000 sample 16 bit and an SDR-X I/Q receiver. With other software (Winrad, Rocky) I must enable 1 sample delay on the right channel to get proper image cancellation. If I don't delay the right channel it's impossible to get more than 15 / 20 dB of cancellation, while with delay ON I can get easily 70 dB on any specific frequency and about 50 dB on the 90k band. I know this problem is typical of most low cost audio card and laptop internal card, while is absent on the Delta 44. I see no way of enabling this delay in Linrad (I am using it currently under Windows). Any help / advice?

Best regards
Alberto I2KBD


#############################################################
This message is sent to you because you are subscribed to
 the mailing list <linrad@antennspecialisten.se>.
To unsubscribe, E-mail to: <[EMAIL PROTECTED]>
To switch to the DIGEST mode, E-mail to <[EMAIL PROTECTED]>
To switch to the INDEX mode, E-mail to <[EMAIL PROTECTED]>
Send administrative queries to  <[EMAIL PROTECTED]>

Reply via email to