Re: WARN when unmounting a subvolume that is being synced

2018-03-14 Thread Tycho Andersen
On Wed, Mar 14, 2018 at 09:46:07AM +0200, Nikolay Borisov wrote: > > > On 14.03.2018 05:10, Tycho Andersen wrote: > > Hi all, > > > > I'm getting the WARN below. I think (?) what I'm doing when I get it > > is that I'm unmounting a subvolume while it's being synced (concurrent > > uses of the

Re: WARN when unmounting a subvolume that is being synced

2018-03-14 Thread Nikolay Borisov
On 14.03.2018 05:10, Tycho Andersen wrote: > Hi all, > > I'm getting the WARN below. I think (?) what I'm doing when I get it > is that I'm unmounting a subvolume while it's being synced (concurrent > uses of the subvolume, at least, happy to look into it further if the > stack trace is not so

WARN when unmounting a subvolume that is being synced

2018-03-13 Thread Tycho Andersen
Hi all, I'm getting the WARN below. I think (?) what I'm doing when I get it is that I'm unmounting a subvolume while it's being synced (concurrent uses of the subvolume, at least, happy to look into it further if the stack trace is not so useful). Anyway, I can fairly reliably reproduce this on