Re: [PATCH] iio: fix pressure data output unit in hid-sensor-attributes

2016-09-03 Thread Jonathan Cameron
On 30/08/16 20:49, Pandruvada, Srinivas wrote: > On Mon, 2016-08-29 at 18:50 +0800, Kweh, Hock Leong wrote: >> From: "Kweh, Hock Leong" >> >> According to IIO ABI definition, IIO_PRESSURE data output unit is >> kilopascal: >> http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs- >>

Re: [PATCH] iio: fix pressure data output unit in hid-sensor-attributes

2016-08-30 Thread Pandruvada, Srinivas
On Mon, 2016-08-29 at 18:50 +0800, Kweh, Hock Leong wrote: > From: "Kweh, Hock Leong" > > According to IIO ABI definition, IIO_PRESSURE data output unit is > kilopascal: > http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs- > bus-iio > > This patch fix output unit of HID pressu

[PATCH] iio: fix pressure data output unit in hid-sensor-attributes

2016-08-28 Thread Kweh, Hock Leong
From: "Kweh, Hock Leong" According to IIO ABI definition, IIO_PRESSURE data output unit is kilopascal: http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio This patch fix output unit of HID pressure sensor IIO driver from pascal to kilopascal to follow IIO ABI definition.