Re: [PATCH RESEND 2/2] mfd: madera: Add special errata reset handling for cs47l15

2020-11-04 Thread Lee Jones
On Tue, 27 Oct 2020, Charles Keepax wrote: > An errata exists for cs47l15 where the reset must be handled > differently and removed before DCVDD is applied. A soft reset is used > for situations where a reset is required to reset state. This does > however, make this part unsuitable for DCVDD

[PATCH RESEND 2/2] mfd: madera: Add special errata reset handling for cs47l15

2020-10-27 Thread Charles Keepax
An errata exists for cs47l15 where the reset must be handled differently and removed before DCVDD is applied. A soft reset is used for situations where a reset is required to reset state. This does however, make this part unsuitable for DCVDD supplies with a rise time greater than 2mS.