Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-12 Thread Javi Merino
Hi Peter, On Mon, May 12, 2014 at 11:27:08AM +0100, Peter Feuerer wrote: > Javi Merino writes: > > On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: > >> acerhdf has been doing an on-off fan control using hysteresis by > >> post-manipulating the outcome of thermal subsystem trip

Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-12 Thread Peter Feuerer
Hi Javi, Javi Merino writes: Hi Peter, On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point handling. This patch enables acerhdf to use the bang-bang

Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-12 Thread Peter Feuerer
Hi Javi, Javi Merino writes: Hi Peter, On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point handling. This patch enables acerhdf to use the bang-bang

Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-12 Thread Javi Merino
Hi Peter, On Mon, May 12, 2014 at 11:27:08AM +0100, Peter Feuerer wrote: Javi Merino writes: On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point

Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-06 Thread Javi Merino
Hi Peter, On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: > acerhdf has been doing an on-off fan control using hysteresis by > post-manipulating the outcome of thermal subsystem trip point handling. > This patch enables acerhdf to use the bang-bang governor, which is > intended for

Re: [PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-06 Thread Javi Merino
Hi Peter, On Sat, May 03, 2014 at 06:59:24PM +0100, Peter Feuerer wrote: acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point handling. This patch enables acerhdf to use the bang-bang governor, which is intended for

[PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-03 Thread Peter Feuerer
acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point handling. This patch enables acerhdf to use the bang-bang governor, which is intended for on-off controlled fans. Cc: Andrew Morton CC: Zhang Rui Cc: Andreas Mohr Cc:

[PATCH v3 4/6] acerhdf: Use bang-bang thermal governor

2014-05-03 Thread Peter Feuerer
acerhdf has been doing an on-off fan control using hysteresis by post-manipulating the outcome of thermal subsystem trip point handling. This patch enables acerhdf to use the bang-bang governor, which is intended for on-off controlled fans. Cc: Andrew Morton a...@linux-foundation.org CC: Zhang