Re: [PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-04 Thread Javier Martinez Canillas
Hello Krzysztof, On 11/04/2014 11:50 AM, Krzysztof Kozlowski wrote: >> + >> +The possible values for "regulator-initial-mode" and "regulator-mode" are: >> +1: Normal regulator voltage output mode. >> +3: Low Power which reduces the quiescent current down to only 1uA >> + >> +The list of

Re: [PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-04 Thread Krzysztof Kozlowski
On pon, 2014-11-03 at 15:40 +0100, Javier Martinez Canillas wrote: > Some regulators from the max77802 PMIC support to be configured in one > of two operating mode: Output ON (normal) and Output On Low Power Mode. > Not all regulators support these two modes and for some of them, the > mode can be

Re: [PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-04 Thread Krzysztof Kozlowski
On pon, 2014-11-03 at 15:40 +0100, Javier Martinez Canillas wrote: Some regulators from the max77802 PMIC support to be configured in one of two operating mode: Output ON (normal) and Output On Low Power Mode. Not all regulators support these two modes and for some of them, the mode can be

Re: [PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-04 Thread Javier Martinez Canillas
Hello Krzysztof, On 11/04/2014 11:50 AM, Krzysztof Kozlowski wrote: + +The possible values for regulator-initial-mode and regulator-mode are: +1: Normal regulator voltage output mode. +3: Low Power which reduces the quiescent current down to only 1uA + +The list of valid modes are

[PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-03 Thread Javier Martinez Canillas
Some regulators from the max77802 PMIC support to be configured in one of two operating mode: Output ON (normal) and Output On Low Power Mode. Not all regulators support these two modes and for some of them, the mode can be changed while the system is running in normal operation while others only

[PATCH v4 11/14] regulator: max77802: Document binding for regulator operating modes

2014-11-03 Thread Javier Martinez Canillas
Some regulators from the max77802 PMIC support to be configured in one of two operating mode: Output ON (normal) and Output On Low Power Mode. Not all regulators support these two modes and for some of them, the mode can be changed while the system is running in normal operation while others only