Re: mxs-auart gives data from previous run after close and reopen

2014-03-21 Thread Peter Hurley
On 03/21/2014 04:21 AM, Stanislav Meduna wrote: On 21.03.2014 02:39, Peter Hurley wrote: Does disabling the fifo on shutdown clear the fifo? I did not try this, but if my theory is correct, it would not help, as all this does is reducing the FIFO length to one character. So you'd still get up

Re: mxs-auart gives data from previous run after close and reopen

2014-03-21 Thread Stanislav Meduna
On 21.03.2014 02:39, Peter Hurley wrote: > Does disabling the fifo on shutdown clear the fifo? I did not try this, but if my theory is correct, it would not help, as all this does is reducing the FIFO length to one character. So you'd still get up to two characters: one in the "FIFO" - it could g

Re: mxs-auart gives data from previous run after close and reopen

2014-03-20 Thread Peter Hurley
On 03/14/2014 04:11 PM, Stanislav Meduna wrote: Hi, following scenario: - a Freescale i.MX28 machine - RS232 AUART looped back Rx - Tx or two different ports cross-connected - a test program sending data in one thread and receiving in the other: thread A periodically sends "Quick brown fox j

mxs-auart gives data from previous run after close and reopen

2014-03-14 Thread Stanislav Meduna
Hi, following scenario: - a Freescale i.MX28 machine - RS232 AUART looped back Rx - Tx or two different ports cross-connected - a test program sending data in one thread and receiving in the other: thread A periodically sends "Quick brown fox jumps over the lazy dog", thread B receives - stop