* H. Nikolaus Schaller [190911 17:48]:
> See DM3730,DM275 data sheet (SPRS685B) footnote (6) in Table 4-19
> which says that ABB must be switched to FBB mode when using the
> OPP1G.
>
> The LOD definition abb_mpu_iva already exists so that we need
> to add plumbing for vbb-supply = <&abb_mpu_iva>
On Wed, Sep 11, 2019 at 12:47 PM H. Nikolaus Schaller
wrote:
>
> See DM3730,DM275 data sheet (SPRS685B) footnote (6) in Table 4-19
> which says that ABB must be switched to FBB mode when using the
> OPP1G.
>
> The LOD definition abb_mpu_iva already exists so that we need
> to add plumbing for vbb
See DM3730,DM275 data sheet (SPRS685B) footnote (6) in Table 4-19
which says that ABB must be switched to FBB mode when using the
OPP1G.
The LOD definition abb_mpu_iva already exists so that we need
to add plumbing for vbb-supply = <&abb_mpu_iva>
and define two voltage vectors for each OPP so that