Hi Jon,
On Tue, Nov 06, 2012 at 02:50:50, Hunter, Jon wrote:
[...]
Why is this? How is the dmtimer TIOCP_CFG register configured on AM33xx?
Is it using smart-idle?
Yes, it is set to smart-idle with wakeup capable mode. (this needs a fixup
since this timer is not wakeup capable) but
On 11/06/2012 01:32 AM, Bedia, Vaibhav wrote:
Hi Jon,
On Tue, Nov 06, 2012 at 02:34:05, Hunter, Jon wrote:
[...]
static struct clock_event_device clockevent_gpt = {
.name = gp_timer,
.features = CLOCK_EVT_FEAT_PERIODIC | CLOCK_EVT_FEAT_ONESHOT,
@@ -142,6 +171,8
On 11/06/2012 03:38 AM, Bedia, Vaibhav wrote:
Hi Jon,
On Tue, Nov 06, 2012 at 02:50:50, Hunter, Jon wrote:
[...]
Why is this? How is the dmtimer TIOCP_CFG register configured on AM33xx?
Is it using smart-idle?
Yes, it is set to smart-idle with wakeup capable mode. (this needs a fixup
On Sunday 04 November 2012 08:55 PM, Bedia, Vaibhav wrote:
Hi Santosh,
On Sat, Nov 03, 2012 at 21:22:04, Shilimkar, Santosh wrote:
On Friday 02 November 2012 06:02 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as
On 11/02/2012 07:32 AM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
AM33XX has only one usable timer in the WKUP domain
so one of the timers needs suspend-resume support
to restore
On 11/03/2012 08:17 AM, Bedia, Vaibhav wrote:
On Sat, Nov 03, 2012 at 17:45:03, Kevin Hilman wrote:
On 11/02/2012 01:32 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
AM33XX has
Hi Jon,
On Tue, Nov 06, 2012 at 02:34:05, Hunter, Jon wrote:
[...]
static struct clock_event_device clockevent_gpt = {
.name = gp_timer,
.features = CLOCK_EVT_FEAT_PERIODIC | CLOCK_EVT_FEAT_ONESHOT,
@@ -142,6 +171,8 @@ static struct clock_event_device
Hi Santosh,
On Sat, Nov 03, 2012 at 21:22:04, Shilimkar, Santosh wrote:
On Friday 02 November 2012 06:02 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
Actually OMAP also uses
On 11/02/2012 01:32 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
AM33XX has only one usable timer in the WKUP domain
so one of the timers needs suspend-resume support
to restore the
On Sat, Nov 03, 2012 at 17:45:03, Kevin Hilman wrote:
On 11/02/2012 01:32 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
AM33XX has only one usable timer in the WKUP domain
so
On 11/03/2012 01:17 PM, Bedia, Vaibhav wrote:
On Sat, Nov 03, 2012 at 17:45:03, Kevin Hilman wrote:
On 11/02/2012 01:32 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
AM33XX has only
On Sat, Nov 03, 2012 at 19:11:54, Kevin Hilman wrote:
[...]
Yes, please try with that. Won't that be necessary anyways for situations
where the powerdomain goes off?
Yes, we probably got lucky with the minimal resume routine.
Regards,
Vaibhav
--
To unsubscribe from this list: send the
On Friday 02 November 2012 06:02 PM, Vaibhav Bedia wrote:
From: Vaibhav Hiremath hvaib...@ti.com
The current OMAP timer code registers two timers -
one as clocksource and one as clockevent.
Actually OMAP also uses only one timer. The clocksource
is taken care by 32K syntimer till OMAP4 and by
13 matches