From: Kazuya Mizuguchi <kazuya.mizuguchi...@renesas.com>

Set PHY rxc-skew-ps to 1500 and all other values to their default values.

This is intended to to address failures in the case of 1Gbps communication
using the by salvator-x board with the KSZ9031RNX phy. This has been
reported to occur with both the r8a7795 (H3) and r8a7796 (M3-W) SoCs.

Signed-off-by: Kazuya Mizuguchi <kazuya.mizuguchi...@renesas.com>
Signed-off-by: Takeshi Kihara <takeshi.kihara...@renesas.com>
Signed-off-by: Simon Horman <horms+rene...@verge.net.au>
---
 arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dts | 13 +------------
 1 file changed, 1 insertion(+), 12 deletions(-)

diff --git a/arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dts 
b/arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dts
index dc1177c76aa5..5158ba3f9ce3 100644
--- a/arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dts
+++ b/arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dts
@@ -497,18 +497,7 @@
        status = "okay";
 
        phy0: ethernet-phy@0 {
-               rxc-skew-ps = <900>;
-               rxdv-skew-ps = <0>;
-               rxd0-skew-ps = <0>;
-               rxd1-skew-ps = <0>;
-               rxd2-skew-ps = <0>;
-               rxd3-skew-ps = <0>;
-               txc-skew-ps = <900>;
-               txen-skew-ps = <0>;
-               txd0-skew-ps = <0>;
-               txd1-skew-ps = <0>;
-               txd2-skew-ps = <0>;
-               txd3-skew-ps = <0>;
+               rxc-skew-ps = <1500>;
                reg = <0>;
                interrupt-parent = <&gpio2>;
                interrupts = <11 IRQ_TYPE_LEVEL_LOW>;
-- 
2.7.0.rc3.207.g0ac5344

Reply via email to