On 19/06/2017 09:23, Johannes Thumshirn wrote:
On Fri, Jun 16, 2017 at 07:57:08PM -0400, Will Simoneau wrote:
Is this is a known / obvious issue, or should I try to bisect it?
Out of curiousity, does this issue also occur when only the disk is
hot-removed from the expander?
This is a
On Fri, Jun 16, 2017 at 07:57:08PM -0400, Will Simoneau wrote:
> Is this is a known / obvious issue, or should I try to bisect it?
This is a known issue with SAS (and FC) drivers, although no soulution exists
to this point.
Johannes
--
Johannes Thumshirn
I've got a disk box with a SAS expander connected to a card based on the
LSI SAS1068E chip. I recently upgraded the machine from 4.5.7 to 4.11.5,
and now disconnecting (i.e. hot removing) the SAS expander from the HBA
results in fireworks like this:
[ 4738.044119] end_device-6:0:0: mptsas:
3 matches
Mail list logo