On 05/16/2018 04:55 AM, Mathias Nyman wrote:
On 15.05.2018 12:22, Michael Tretter wrote:
Hi Mathias,
On Tue, 10 Apr 2018 18:22:03 +0300, Mathias Nyman wrote:
On 09.04.2018 11:21, Michael Tretter wrote:
On Tue, 20 Feb 2018 15:29:28 +0200, Mathias Nyman wrote:
On 16.02.2018 15:28, Michael
On 11/08/2017 12:19 PM, Curt Meyers wrote:
On 11/08/2017 03:42 AM, Mathias Nyman wrote:
On 07.11.2017 02:05, Curt Meyers wrote:
On 11/06/2017 06:57 AM, Mathias Nyman wrote:
On 03.11.2017 23:37, Curt Meyers wrote:
On 09/19/2017 06:00 AM, Mathias Nyman wrote:
On 08.09.2017 20:35, Curt Meyers
On 11/08/2017 03:42 AM, Mathias Nyman wrote:
On 07.11.2017 02:05, Curt Meyers wrote:
On 11/06/2017 06:57 AM, Mathias Nyman wrote:
On 03.11.2017 23:37, Curt Meyers wrote:
On 09/19/2017 06:00 AM, Mathias Nyman wrote:
On 08.09.2017 20:35, Curt Meyers wrote:
On 09/05/2017 02:56 PM, Curt Meyers
On 11/06/2017 06:57 AM, Mathias Nyman wrote:
On 03.11.2017 23:37, Curt Meyers wrote:
On 09/19/2017 06:00 AM, Mathias Nyman wrote:
On 08.09.2017 20:35, Curt Meyers wrote:
On 09/05/2017 02:56 PM, Curt Meyers wrote:
On 09/04/2017 04:13 AM, Mathias Nyman wrote:
On 04.09.2017 13:46, Felipe Balbi
On 09/19/2017 06:00 AM, Mathias Nyman wrote:
On 08.09.2017 20:35, Curt Meyers wrote:
On 09/05/2017 02:56 PM, Curt Meyers wrote:
On 09/04/2017 04:13 AM, Mathias Nyman wrote:
On 04.09.2017 13:46, Felipe Balbi wrote:
Hi,
Mathias Nyman <mathias.ny...@linux.intel.com> writes:
Unfortu
On 09/05/2017 02:56 PM, Curt Meyers wrote:
On 09/04/2017 04:13 AM, Mathias Nyman wrote:
On 04.09.2017 13:46, Felipe Balbi wrote:
Hi,
Mathias Nyman <mathias.ny...@linux.intel.com> writes:
Unfortunately config endpoint command doesn't log endpoint context
in this log,
it shoul
On 08/28/2017 06:00 AM, Mathias Nyman wrote:
On 19.07.2017 01:39, Curt Meyers wrote:
Hello,
I have a new USB3 camera that can only operate in isochronous mode. I
can open and stream data from the camera using guvcview. The camera
has 3 interfaces, two show up as uvc video devices
Hello,
I have a new USB3 camera that can only operate in isochronous mode. I
can open and stream data from the camera using guvcview. The camera has
3 interfaces, two show up as uvc video devices. The interface I open
claims a maximum bandwidth dwMaxBitRate=73728000, I should be able to
open