On Thu, 03 Jun 2004 12:35:30 -0400
David van Hoose <[EMAIL PROTECTED]> wrote:
> I have been receiving the following weird message when connecting or
> disconnecting my USB HP All-in-one.
>
> usb: raced timeout, pipe 0x8280 status 0 time left 0
Strictly speaking, it can happen infrequently on
David van Hoose wrote:
usb: raced timeout, pipe 0x8280 status 0 time left 0
The synchronous control/bulk logic in 2.4 isn't correct in all
cases ... it'd be good to just merge what 2.6 uses. That "raced"
is an indication that you've hit a software bug.
- Dave
-