On Mon, Jul 22, 2019 at 3:58 PM Lucas Stach wrote:
>
> Am Montag, den 22.07.2019, 15:48 +0300 schrieb Daniel Baluta:
> > SAI supports up to 8 Rx/Tx data lines which can be enabled
> > using TCE/RCE bits of TCR3/RCR3 registers.
> >
> > Data lines to be enabled are read from DT fsl,dl_mask
Am Montag, den 22.07.2019, 15:48 +0300 schrieb Daniel Baluta:
> SAI supports up to 8 Rx/Tx data lines which can be enabled
> using TCE/RCE bits of TCR3/RCR3 registers.
>
> Data lines to be enabled are read from DT fsl,dl_mask property.
> By default (if no DT entry is provided) only data line 0 is
SAI supports up to 8 Rx/Tx data lines which can be enabled
using TCE/RCE bits of TCR3/RCR3 registers.
Data lines to be enabled are read from DT fsl,dl_mask property.
By default (if no DT entry is provided) only data line 0 is enabled.
Note:
We can only enable consecutive data lines starting with